PIKO CI 30 / 50 / 60 commercial grid-tied inverters, 33–66 kVA
Country: Germany · Model: PIKO CI 30 / 50 / 60
PIKO CI three-phase grid-tied inverters deliver 33 kVA (CI 30), 55 kVA (CI 50) and 66 kVA (CI 60) at over 98 % efficiency. They go into small and mid-size business PV plants with arrays from 45 to 90 kWp.
- Power
- 33 kVA (CI 30), 55 kVA (CI 50), 66 kVA (CI 60)
- DC inputs
- up to 12
- MPP range
- 180–960 V
- System voltage
- up to 1100 V (CI 30: 1000 V)
Technical specifications
| Power | 33 kVA (CI 30), 55 kVA (CI 50), 66 kVA (CI 60) |
|---|---|
| DC inputs | up to 12 |
| MPP range | 180–960 V |
| System voltage | up to 1100 V (CI 30: 1000 V) |
| Efficiency | > 98 % |
| DC/AC oversizing | up to 50 % |
| More from the manufacturer’s documentation | |
| Max. PV power | 45 / 75 / 90 kWp (CI 30 / 50 / 60) |
| MPP trackers | 2 (CI 30) / 4 (CI 50, CI 60) |
| Rated input voltage | 620 V |
| Start-up voltage | 250 V |
| Max. input current per MPPT | 40.5 A (CI 30) / 39 and 26 A (CI 50) / 39 A (CI 60) |
| Max. current per DC terminal | 18 A |
| Internal DC string fuses | 20 A (10 × 38 mm, gPV) |
| Grid connection | 3N~, 230/400 V, 50 Hz |
| Rated AC current | 43.3 / 72.2 / 86.6 A (CI 30 / 50 / 60) |
| Grid frequency range | 47–53 Hz |
| Power factor range | 0.8…1…0.8 |
| Max. THD | < 3 % |
| Night-time consumption | < 1 W |
| Max. efficiency | 98.2 % (CI 30) / 98.3 % (CI 50, CI 60) |
| European efficiency | 97.9 % (CI 30) / 98.1 % (CI 50, CI 60) |
| Protection rating | IP65 |
| Protection | RCMU/RCCB type B, type 2 surge protection (AC and DC) |
| Dimensions (H × W × D) | 470 × 555 × 270 mm (CI 30) / 710 × 885 × 285 mm (CI 50) / 710 × 855 × 285 mm (CI 60) |
| Weight | 41 kg (CI 30) / 83 kg (CI 50, CI 60) |
| Noise emission | 50 dB(A) (CI 30) / < 63 dB(A) (CI 50, CI 60) |
| Operating temperature | −25…+60 °C |
| Max. installation altitude | 4,000 m |
| Relative humidity | 0–100 % |
| Max. output fuse | B63/C63 (CI 30) / B125/C125 (CI 50, CI 60) |
| DC connectors | Amphenol H4 |
| Interfaces | 2 × LAN (RJ45), Wi-Fi, RS485, 4 digital inputs |
| Warranty | 5 years (+ 5 years optional) |
| Certifications | EN 62109-1/-2, VDE-AR-N 4105:2018, VDE-AR-N 4110 (CI 50/60 — 2023 unit certificate), EN 50549-1/-2, CEI 0-16, CEI 0-21, G99, IEC 61727/62116 |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504408800 (>7.5 kVA) |
| CN code (EU) | 85044084 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Up to 12 DC inputs connect, with an MPP range of 180–960 V, 620 V rated input and 250 V start-up. System voltage is allowed up to 1,100 V, or 1,000 V on the smaller CI 30, and strings for that model are sized to this limit. The module array can be sized with DC/AC oversizing of up to 50 %. Each input has a built-in 20 A gPV fuse, input current is capped at 18 A, and each tracker takes up to 40.5 A on the CI 30 and 39 A on the larger models. Type 2 surge arresters sit on AC and DC, with RCMU type B leakage monitoring. A built-in Smart Communication Board links to monitoring over 2 LAN ports, Wi-Fi and RS485. The IP65 housing weighs 41 kg on the CI 30 and 83 kg on the others.
How to choose
Pick the model by the array, 45, 75 or 90 kWp, and by rated AC current of 43.3 / 72.2 / 86.6 A, which sets a B63/C63 breaker on the CI 30 and B125/C125 on the others. The CI 30 has two trackers and the CI 50 and CI 60 four each, so roofs with several orientations suit the larger models. The newer PIKO CI G2 at 30 and 50 kW takes 40 A per MPPT. Sites from 100 kW go to the PIKO CI 100.
Request a price and lead time
PIKO CI 30 / 50 / 60 commercial grid-tied inverters, 33–66 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the MPP range of PIKO CI inverters?
The MPP range is 180–960 V with system voltage up to 1,100 V, or 1,000 V on the CI 30.
How much DC/AC oversizing does the PIKO CI 50 accept?
Up to 50 %, with the CI 50 rated at 55 kVA and taking arrays up to 75 kWp.
How many DC inputs does the PIKO CI 60 have?
Up to 12 DC inputs on 4 trackers, with the model rated at 66 kVA.
Do PIKO CI inverters need external string fuses?
No, 20 A gPV fuses sized 10 × 38 mm are built in.
How much does the PIKO CI 50 weigh?
83 kg like the CI 60, against 41 kg for the CI 30, with noise below 63 dB(A).
Similar products
REQUEST
Need a price, lead time or replacement?