Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

PIKO CI G2 commercial grid-tied inverter, 30 / 50 kW

The PIKO CI G2 three-phase grid-tied inverter comes in 30 and 50 kW ratings with 98.2 % peak efficiency and an IP66 housing. This second-generation unit mounts outdoors and serves small and mid-size commercial PV plants with arrays up to 45 or 75 kWp.

Power
30 and 50 kW
Max. efficiency
98.2 %
System voltage
up to 1100 V (operating up to 1000 V)
Input current
up to 40 A per MPPT, 20 A per input

Technical specifications

Power30 and 50 kW
Max. efficiency98.2 %
System voltageup to 1100 V (operating up to 1000 V)
Input currentup to 40 A per MPPT, 20 A per input
Surge protectiontype 2 (AC and DC)
Temperature−25…+60 °C
More from the manufacturer’s documentation
Max. PV power45 kWp (CI 30) / 75 kWp (CI 50)
MPP trackers3 (CI 30) / 4 (CI 50)
DC inputs6 (CI 30) / 8 (CI 50)
Rated input voltage620 V
Start-up voltage200 V
MPP range at rated output420–850 V (CI 30) / 500–850 V (CI 50)
Min. working voltage180 V
Apparent output power33.4 kVA (CI 30) / 55.6 kVA (CI 50)
Grid connection3N~, 230/400 V, 50 Hz
Rated AC current43.5 A (CI 30) / 72.5 A (CI 50)
Grid frequency range45–55 Hz
Power factor range0.8…1…0.8
Max. THD< 3 %
Night-time consumption< 10 W
European efficiency97.8 %
Protection ratingIP66
Topologytransformerless
ProtectionRCMU/RCCB type B, DC arc detection (AFCI)
Dimensions (H × W × D)530 (707) × 635 × 224 mm
Weight33.1 kg (CI 30) / 44.3 kg (CI 50)
Noise emission< 35 dB(A) (CI 30) / < 50 dB(A) (CI 50)
Max. installation altitude4,000 m
Relative humidity0–100 %
Max. output fuseB63/C63 (CI 30) / B125/C125 (CI 50)
DC connectorsAmphenol H4
Interfaces2 × LAN (RJ45), 2 × RS485, 4 digital inputs
Warranty5 years (+ 5 years optional)
CertificationsIEC 62109-1/-2, VDE-AR-N 4105, VDE-AR-N 4110, EN 50549-1/-2, CEI 0-16, CEI 0-21, IEC 61727/62116
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

System voltage is allowed up to 1,100 V with operation up to 1,000 V, so strings can be long at a 620 V rated input. Each MPPT takes up to 40 A and each input 20 A, enough for high-current modules. The CI 30 has three trackers and 6 inputs, the CI 50 four trackers and 8 inputs, with MPP ranges at rated output of 420–850 V and 500–850 V. Type 2 surge protection sits on both AC and DC, an RCMU type B watches leakage, and AFCI arc detection trips the DC circuit on arcing. The inverter runs at ambient temperatures from −25 to +60 °C and up to 4,000 m, so no separate room is needed. The 3N~ 230/400 V output gives 33.4 kVA on the CI 30 and 55.6 kVA on the CI 50 at 43.5 A and 72.5 A rated current.

How to choose

Pick the model by the array, up to 45 kWp on the CI 30 and 75 kWp on the CI 50, and size the breaker at B63/C63 or B125/C125. The earlier PIKO CI 30 / 50 / 60 series reaches 66 kVA and 12 DC inputs when one unit needs more headroom. For backup or a battery take the PLENTICORE G3 hybrid up to 20 kW. Plants at 100 kW are covered by the PIKO CI 100.

Request a price and lead time

PIKO CI G2 commercial grid-tied inverter, 30 / 50 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the efficiency of the PIKO CI G2 inverter?

Peak efficiency is 98.2 % and European efficiency 97.8 %.

What is the maximum DC voltage of the PIKO CI G2?

System voltage up to 1,100 V, operating up to 1,000 V, start-up at 200 V.

What temperature range does the PIKO CI G2 handle?

From −25 to +60 °C at 0–100 % humidity, and the inverter is installed outdoors.

Does the PIKO CI G2 have arc fault protection?

Yes, it has DC arc detection (AFCI) and RCMU type B leakage monitoring built in.

How much does the PIKO CI G2 weigh?

33.1 kg for the CI 30 and 44.3 kg for the CI 50, at 635 mm width and below 35 and 50 dB(A) of noise.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.