X1 LV (X1-HYB LV, X1-Lite-LV, X1-RENO-LV) — single-phase hybrid inverters, 3–12 kW, for 48 V batteries

Three single-phase hybrid inverters for 48 V batteries cover power from 3 to 12 kW. The X1 LV series is installed in houses where backup is built on a low-voltage battery and a generator or microgrid is part of the power scheme.

Power
3–6 kW (HYB LV), 8–12 kW (Lite-LV), 8 kW (RENO-LV)
MPPT
2 (16 A) / 3 (32 A)
EPS peak power
2× rated, 10 s
Switchover
< 4 ms (HYB LV), < 6 ms (Lite-LV)

Technical specifications

Power3–6 kW (HYB LV), 8–12 kW (Lite-LV), 8 kW (RENO-LV)
MPPT2 (16 A) / 3 (32 A)
EPS peak power2× rated, 10 s
Switchover< 4 ms (HYB LV), < 6 ms (Lite-LV)
Ingress protectionIP65 (HYB LV)
Parallel operationup to 3–5 units
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The smaller X1-HYB LV comes in ratings of 3–6 kW, with an IP65 housing and switchover to backup in under 4 ms. The X1-Lite-LV covers the 8–12 kW range and goes into off-grid mode within 6 ms, while the X1-RENO-LV is made for 8 kW. The solar array is connected to two 16 A trackers or three 32 A trackers, depending on the model. In EPS mode the inverter delivers double its rated power for 10 s, so it can handle starting pumps and compressors. A backup generator is connected to the generator input, and the inverter coordinates its operation with the battery and PV. Several units can be paralleled, from 3 to 5 depending on the model.

How to choose

The first thing that decides the choice is the load power. Up to 6 kW the X1-HYB LV is enough, for 8–12 kW the X1-Lite-LV is taken, and the 8 kW RENO-LV is considered as an alternative in the same class. If the house has three phases, the single-phase line will not do, and then the three-phase low-voltage X3-NEO-LV or the X3-HYBRID G4 rated 5–15 kW with parallel operation up to 150 kW should be considered.

Request a price and lead time

X1 LV (X1-HYB LV, X1-Lite-LV, X1-RENO-LV) — single-phase hybrid inverters, 3–12 kW, for 48 V batteries. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which battery is needed for X1 LV inverters?

The inverters of the series are designed for 48 V batteries, that is, low-voltage racks and wall-mounted modules. High-voltage batteries are not connected to them.

How fast does the X1-HYB LV switch to backup when the grid is lost?

The switchover time of the X1-HYB LV is under 4 ms, and for the X1-Lite-LV up to 6 ms. Such a transition usually passes without restarting household appliances.

Can a generator be connected to the X1 LV?

Yes, the series has a generator input and works in microgrid mode. The generator backs up the battery during long outages.

How many X1 LV inverters can be connected in parallel?

Parallel operation is supported for 3–5 units depending on the model. This is how a single-phase system is expanded without replacing the inverter already installed.

What peak power does the X1-Lite-LV deliver in EPS mode?

For 10 s the inverter delivers twice its rating. For the 12 kW model this is a margin for starting powerful motors.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.