MultiPlus-II — inverter/charger 3–15 kVA with ESS function

The MultiPlus-II inverter/charger, rated 3–15 kVA, runs from 12, 24 or 48 V batteries and outputs a clean 230 V sine wave. It goes into energy storage systems with the ESS function, off-grid and backup setups, boats and vehicles.

Power
3–15 kVA (models 12/3000 … 48/15000)
Battery voltage
12, 24, 48 V
Output
230 V sine wave
Functions
ESS, PowerControl/PowerAssist up to 100 A, built-in anti-islanding protection

Technical specifications

Power3–15 kVA (models 12/3000 … 48/15000)
Battery voltage12, 24, 48 V
Output230 V sine wave
FunctionsESS, PowerControl/PowerAssist up to 100 A, built-in anti-islanding protection
Scalingparallel and 3-phase
Ingress protectionIP22
CertificatesIEC 62477, EN 50549-1, G99, PTPiREE, etc.
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044087

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The range runs from the 12/3000 to the 48/15000, where the first figure is the battery voltage and the second the rating in VA. With inverter, charger and transfer switch in one enclosure, the unit acts as a UPS when the grid drops. PowerControl and PowerAssist cap the current drawn from the grid or generator at up to 100 A and add battery power at peaks, so the generator or grid connection can be rated below the site’s peak demand. The IEC 62477, EN 50549-1, G99, PTPiREE and other certificates are needed to get grid connection approved. The IP22 enclosure belongs in a dry room — a plant room, utility closet or boat compartment. Several units connect in parallel for more power or form a system on 3 phases.

How to choose

Start with the battery voltage. 12 V suits the smaller units in mobile systems, while toward 15 kVA a 48 V bank keeps DC bus current four times lower. If the generator needs its own input, look at the Quattro with two AC inputs and a built-in grid/generator transfer switch. The MultiPlus-II GX saves a separate system controller, and the EasySolar-II GX also fits an MPPT 250/70 or 250/100 into the same enclosure. A three-phase site with a high-voltage battery suits the 15 kW Multi HS19 Solar 15k hybrid inverter.

Request a price and lead time

MultiPlus-II — inverter/charger 3–15 kVA with ESS function. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What battery voltage does the MultiPlus-II use?

12, 24 or 48 V depending on the model, shown by the first figure in the name, as in 48/15000.

Up to what current does PowerAssist work in the MultiPlus-II?

PowerControl and PowerAssist work with input current up to 100 A. The inverter takes the rest from the battery.

Does the MultiPlus-II have anti-islanding protection?

Yes, it is built in, with EN 50549-1 and G99 certificates.

Can the MultiPlus-II be used in a three-phase system?

Yes, units connect in parallel and in a 3-phase system. That is how you go beyond the 15 kVA of a single unit.

Can the MultiPlus-II be installed outdoors?

The enclosure is rated IP22, so it is mounted indoors. Outdoors it needs a protective cabinet.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.