Quattro-II — inverter/charger with two inputs and ESS function

The Quattro-II inverter/charger has 2 AC inputs, one for the grid and one for a generator, and comes as 24/5000/120-50, 48/5000/70-50 and other models. It is the new Quattro generation with support for energy storage systems (ESS), chosen for sites where a generator is permanently installed and works alongside the grid.

Models
24/5000/120-50, 48/5000/70-50, etc.
AC inputs
2 (grid/generator)
Functions
ESS, PowerControl/PowerAssist

Technical specifications

Models24/5000/120-50, 48/5000/70-50, etc.
AC inputs2 (grid/generator)
FunctionsESS, PowerControl/PowerAssist
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044087

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Grid and generator land on separate terminals, and the unit selects the active input and moves the load between them on its own. When the grid fails the battery carries the load, and once the generator starts the inverter switches to the second input and charges the bank at the same time. In ESS mode the inverter charges and discharges the battery on commands from a system controller, for example storing daytime solar energy for the evening. PowerControl and PowerAssist limit the draw from a weak source and add battery power on top, so a small generator is not overloaded when a pump or compressor starts. In 24/5000/120-50 the figure 120 is the charge current in amps and 50 the transfer switch current, while the 48/5000/70-50 charges at up to 70 A. The Quattro-II goes onto farms, bases and country houses with a backup generator and solar generation.

How to choose

The second input only matters where a generator is permanently connected. Without a generator, a MultiPlus-II with one input and PowerAssist up to 100 A is simpler. Between models the bank decides, with the 24/5000/120-50 for 24 V batteries and the 48/5000/70-50 for 48 V, where DC-side currents are half as high. The previous Quattro generation at 3–15 kVA fits when one unit must deliver more than 5 kVA or offer 2 outputs, the main one switching without a break in < 20 ms.

Request a price and lead time

Quattro-II — inverter/charger with two inputs and ESS function. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many inputs does the Quattro-II have?

2 AC inputs, for grid and generator.

Does the Quattro-II support ESS mode?

Yes, ESS is supported along with PowerControl and PowerAssist, and a system controller runs battery charge and discharge.

Which Quattro-II models are available for 48 V?

For example the 48/5000/70-50, and for 24 V there is the 24/5000/120-50.

Do I need a transfer switch to connect a generator to the Quattro-II?

No, the generator lands on its own input and the inverter selects the source itself.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.