Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

AC PowerCube 24 V — modular industrial inverter, 4–14 kVA

An industrial inverter with a 24 V battery input, rated 4, 7 or 14 kVA (models 24/4000, 24/7000 and 24/14000), built for continuous duty in harsh conditions. The 7 and 14 kVA units are made of parallel 3.5 kW modules that back each other up. On a vessel it lets the crew shut the diesel generator down for long periods and run the 230 V network from batteries.

Models
24/4000, 24/7000, 24/14000 VA
Battery voltage
24 V
Architecture
3.5 kW modules, parallel redundancy
Power (24/7000)
6,000 W continuous, 7,500 W P30, 15,000 W peak for 20 s

Technical specifications

Models24/4000, 24/7000, 24/14000 VA
Battery voltage24 V
Architecture3.5 kW modules, parallel redundancy
Power (24/7000)6,000 W continuous, 7,500 W P30, 15,000 W peak for 20 s
Output230 V ±5%, 50 Hz (60 Hz selectable)
Efficiency> 85%, peak > 92%
Technologyhigh-frequency switch-mode
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044087

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The 24/7000 delivers 6,000 W continuous, 7,500 W in P30 mode and up to 15,000 W peak for 20 s. Output is 230 V ±5% at 50 Hz, and the frequency can be reset to 60 Hz for US-standard equipment. The topology is high-frequency switch-mode, with efficiency above 85% and peak efficiency above 92%. Running the modules in parallel gives redundancy inside the inverter itself, so the loss of one block does not black out the whole load. At full power it draws hundreds of amps from the 24 V bus, so the battery cable is short, oversized and fused.

How to choose

Size the unit by the continuous load on the 230 V network, then check the 15,000 W peak of the 24/7000 against the heaviest motor start. If you also need shore charging and automatic transfer to the grid, look at the WPC, an inverter-charger for 12, 24 or 48 V rated 2,000–8,000 VA with 50–160 A of charge current. Individual loads of 500–3,000 W are covered by the WP-Sine. The Supreme Combi, 2,000–3,000 W with transfer under 30 ms, fits where a compact combined unit is wanted.

Request a price and lead time

AC PowerCube 24 V — modular industrial inverter, 4–14 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What continuous and peak power does the AC PowerCube 24/7000 deliver?

It delivers 6,000 W continuous and 7,500 W in P30 mode. Peak power reaches 15,000 W for 20 s.

What modules are the 7 and 14 kVA AC PowerCube units built from?

They use parallel 3.5 kW modules with mutual redundancy.

What is the efficiency of the AC PowerCube 24 V inverter?

Efficiency is above 85%, with a peak above 92%. The design is high-frequency switch-mode.

Can the AC PowerCube output be switched to 60 Hz?

Yes, the standard 230 V 50 Hz output can be set to 60 Hz, with ±5% voltage tolerance.

What happens to the load if one AC PowerCube module fails?

The 3.5 kW modules run in parallel, so the rest keep feeding the network at reduced power instead of a total blackout.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.