Sunny Central FLEX — modular power conversion system for PV and BESS

The Sunny Central FLEX modular platform is assembled from AC/DC and DC/DC converters and works as a megawatt-class power conversion system. A sample configuration delivers 7.36 MW DC/AC plus 6 MW DC/DC for a solar plant with storage. It is used on large hybrid plants connected at medium voltage.

Composition
AC/DC and DC/DC converters
Applications
PV, PV+storage (DC/AC), stand-alone storage, Power2Gas
Semiconductors
SiC
Functions
grid-forming

Technical specifications

CompositionAC/DC and DC/DC converters
ApplicationsPV, PV+storage (DC/AC), stand-alone storage, Power2Gas
SemiconductorsSiC
Functionsgrid-forming
Example7.36 MW DC/AC + 6 MW DC/DC
More from the manufacturer’s documentation
Datasheet versionUL (US): PCU Solar 6400 UL / 6720 UL / 7040 UL
PCU power at 35 °C / 50 °C6,400 / 5,760 kVA, 6,720 / 6,048 kVA, 7,040 / 6,336 kVA
Max. DC voltage1,500 V
MPP voltage range878–1,325 V to 962–1,325 V depending on model
Number of DC inputs36 or 48
Max. DC:AC ratio200%
Max. DC current / short-circuit current2 × 3,720 A / 2 × 10,000 A
Nominal AC voltage (LV)600 / 630 / 660 V
Power factoradjustable 0.8 overexcited to 0.8 underexcited
Max. efficiencyup to 99.4%
MV transformervector groups Dy11y11, YNd11d11, YNy0y0; KFAF cooling
MV voltage12–34.5 kV
Grid frequency60 Hz (57–63 Hz)
Total harmonic distortion< 3% at rated power
Dimensions (L × W × H)12.2 × 2.4 × 2.9 m (40-foot high-cube container)
Weight23 t (depending on options)
Operating temperature−25 °C to +55 °C (extended −40 °C to +55 °C)
Storage temperature−40 °C to +70 °C
Sound pressure level65 dB(A) at 10 m / 50 dB(A) at 50 m
Degree of protectionNEMA 3R (IP54)
Inputs / outputs4 analog inputs, 12 digital inputs, 4 digital outputs
System Managerup to 100 devices; Modbus TCP (SunSpec), DNP3, IEC 60870, IEC 61850, OPC UA, MQTT
Enclosure / roof colorRAL 9016 / RAL 7004
StandardsUL 62109-1, UL 1741, UL 1741 SB, UL 1998, IEEE 1547, FCC Part 15 Class A; cybersecurity IEC 62443
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

One platform covers a pure PV plant, PV plus storage via DC/AC, stand-alone storage and Power2Gas projects. The converters are built on SiC semiconductors, with peak efficiency up to 99.4%. The platform supports grid-forming and can build the grid itself without an external voltage source. The module set is matched to each hybrid power plant. The block arrives in a 40-foot high-cube container of 12.2 × 2.4 × 2.9 m weighing about 23 t, together with a 12–34.5 kV MV transformer. The DC side takes up to 1,500 V on 36 or 48 inputs with a DC:AC ratio up to 200%. The System Manager handles up to 100 devices and talks Modbus TCP, DNP3, IEC 60870, IEC 61850, OPC UA and MQTT. The datasheet covers the UL version for the US at 60 Hz, so figures for a 50 Hz grid are confirmed separately.

How to choose

Pick the PCU version by output at the site summer temperature. The PCU Solar 6400 UL drops from 6,400 kVA at 35 °C to 5,760 kVA at 50 °C, and the 7040 UL from 7,040 to 6,336 kVA. The LV voltage of 600, 630 or 660 V and the transformer vector group Dy11y11, YNd11d11 or YNy0y0 follow the grid operator requirements. Without grid-forming or DC/DC battery coupling, a Sunny Central UP up to 4,600 kVA is simpler, and a stand-alone BESS can use the Sunny Central Storage UP-S up to 5,000 kVA.

Request a price and lead time

Sunny Central FLEX — modular power conversion system for PV and BESS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which converters make up the Sunny Central FLEX?

AC/DC and DC/DC modules, for example 7.36 MW DC/AC plus 6 MW DC/DC in one plant.

Does the Sunny Central FLEX support grid-forming?

Yes, the SiC-based platform supports grid-forming and holds the grid without an external voltage source.

Where is the Sunny Central FLEX used?

In PV plants, PV plus storage, stand-alone storage and Power2Gas projects.

What medium voltage does the Sunny Central FLEX connect to?

The built-in MV transformer covers 12–34.5 kV with KFAF cooling. Vector groups are Dy11y11, YNd11d11 or YNy0y0.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.