Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

Phoenix Inverter Smart / Compact — inverters 1,200–5,000 VA

Phoenix Inverter Smart and Compact sine wave inverters are rated 1,200–5,000 VA. Their high surge power is sized for compressors, electric motors and power tools.

Power
1,200–5,000 VA
Topology
full bridge + toroidal transformer (SinusMax)
Output
210–245 V, 50/60 Hz, sine wave
Parallel
up to 6 units, 3 phases

Technical specifications

Power1,200–5,000 VA
Topologyfull bridge + toroidal transformer (SinusMax)
Output210–245 V, 50/60 Hz, sine wave
Parallelup to 6 units, 3 phases
CommunicationBluetooth (Smart), VE.Direct
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA)
CN code (EU)85044087

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The circuit uses a full bridge with a toroidal transformer in SinusMax technology. The low-frequency transformer carries motor inrush current and separates the battery side from the AC output. Output is 210–245 V at 50/60 Hz, pure sine wave. Up to 6 inverters run in parallel, and the same units can form a 3-phase system. The Smart version is set up over Bluetooth, and the system link runs over VE.Direct. The Compact version has no Bluetooth and is configured through VE.Direct from a computer or a GX controller. With no charger inside, the inverter goes into systems where an MPPT controller or a separate charger looks after the battery.

How to choose

Size the inverter by running load and by the starting current of the largest motor. Loads below 1,600 VA only need the Phoenix Inverter VE.Direct from 250 VA. When the system must also charge from the grid and switch over like a UPS, the MultiPlus or the MultiPlus-II at 3–15 kVA is the next step. For an off-grid site with PV, the Inverter RS Smart Solar 48/6000 adds 2 PV inputs of 3 kWp each in an 11 kg case.

Request a price and lead time

Phoenix Inverter Smart / Compact — inverters 1,200–5,000 VA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many Phoenix Inverters can run in parallel?

Up to 6 units, including in a 3-phase system.

What output voltage does the Phoenix Inverter Compact have?

210–245 V, 50/60 Hz, pure sine wave.

What power ratings does the Phoenix Inverter Smart cover?

The series covers 1,200–5,000 VA and handles motor inrush currents with its toroidal transformer.

What is the difference between Phoenix Inverter Smart and Compact?

The Smart version is set up over Bluetooth, the Compact through VE.Direct. Both use a full bridge with a toroidal transformer.

Can a Phoenix Inverter Smart start a compressor?

Yes, its high surge power is sized for compressors, electric motors and power tools. The motor starting current is still checked against the chosen rating.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.