Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

MIN XH/XA single-phase inverter supporting high-voltage batteries, 2.5–11.4 kW

The MIN XH/XA single-phase inverter of 2.5–11.4 kW is prepared to work with a high-voltage APX or ARK battery. The battery is connected right at the solar plant installation or later, without replacing the inverter.

AC power
2.5–6 kW (XH2/XA), 3–11.4 kW (XH-US)
Phases
1
Batteries
high-voltage APX/ARK
Max. efficiency
up to 98.5 %

Technical specifications

AC power2.5–6 kW (XH2/XA), 3–11.4 kW (XH-US)
Phases1
Batterieshigh-voltage APX/ARK
Max. efficiencyup to 98.5 %
ModesDC- and AC-coupled systems; XA is AC-coupled for retrofit
Ingress protectionIP65–IP66
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The XH2 and XA versions deliver 2.5–6 kW, and the XH-US version for the North American market has a range of 3–11.4 kW. The maximum efficiency reaches 98.5 %. In a DC-coupled scheme the battery is charged from the panels through a common DC bus, without double energy conversion. The XA version works as AC-coupled and is installed next to a grid-tied inverter that is already running, so an old solar plant is upgraded without dismantling. The IP65–IP66 enclosure is designed for outdoor mounting on a house wall. APX and ARK batteries are high-voltage, so currents between the inverter and the storage are small and the cables are thinner than in 48 V systems.

How to choose

The choice starts with whether the site already has a solar plant. For a new plant take the XH2 of the required power within 2.5–6 kW, and for an existing grid-tied system the XA. If the supply has three phases, a three-phase hybrid WIT of 4–25 kW is needed, and for an off-grid house with a 48 V battery the off-grid SPF ES or SPF TL are better suited.

Request a price and lead time

MIN XH/XA single-phase inverter supporting high-voltage batteries, 2.5–11.4 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Can a battery be connected to the MIN XH later?

Yes, the inverter is battery ready, so a high-voltage APX or ARK battery can be added at any time after the solar plant is started.

How does the MIN XA differ from the MIN XH2?

The XA works in an AC-coupled scheme and is intended for upgrading an existing solar plant, while the XH2 connects the battery via the DC bus. The power of both is 2.5–6 kW.

Which batteries are compatible with the MIN XH inverter?

The inverter works with high-voltage APX and ARK batteries. Low-voltage batteries are not suitable for it.

What is the efficiency of the single-phase MIN XH inverter?

The maximum efficiency is up to 98.5 %, so in grid mode without a battery the conversion losses are small.

Can the MIN XH be installed outdoors?

Yes, IP65–IP66 protection is designed for outdoor installation. It is advisable to add a visor above the inverter against direct sun.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.