Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

MIN 2500–10000TL-X/X2 single-phase grid-tied solar inverter, 2.5–10 kW

Single-phase grid-tied inverter for 2.5–10 kW AC output with two or three MPPTs and efficiency up to 98.4 %. The MIN TL-X/X2 series goes on rooftop PV systems of private houses where the operator limits feed-in to the grid, and the X2 Pro version is already prepared for connecting a battery.

AC power
2500–10000 W
Phases
1
MPPT
2–3
Max. DC voltage
500–550 V

Technical specifications

AC power2500–10000 W
Phases1
MPPT2–3
Max. DC voltage500–550 V
Max. efficiencyup to 98.4 %
ProtectionType II SPD on the DC side, AFCI optional
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Ratings run from 2500 to 10000 W per phase, so the model is chosen for the roof area and the permitted connection power. Two or three independent trackers take module strings from different roof slopes, and the panels on the east do not pull down the panels on the west. The upper DC voltage limit is 500–550 V depending on the model, and it sets how many modules can be connected in series allowing for a frosty winter. The export limiting function stops the inverter from feeding more into the grid than agreed with the operator. A Type II SPD is fitted at the DC input, and the AFCI arc fault detector is added as an option, which makes sense for roofs with wooden structures. The X2 Pro version can be fitted with a storage battery later without replacing the inverter.

How to choose

The model is chosen by AC power and the number of MPPTs. Two trackers are enough for a simple two-slope roof, while a complex roof with several planes needs the three-tracker version. If the house must keep running during outages, take the single-phase hybrid SPH/SPM, and for a site with no grid at all take the off-grid SPF ES for 3500–6000 VA with a 48 V battery.

Request a price and lead time

MIN 2500–10000TL-X/X2 single-phase grid-tied solar inverter, 2.5–10 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many MPPTs does the MIN TL-X inverter have and why are there several?

Two or three depending on the rating. Each tracker works with its own string, so modules with different orientation or string length do not reduce each other's output.

What is the maximum DC voltage of the MIN 2500–10000TL-X?

500–550 V depending on the model. The string length is calculated so that the open-circuit voltage of the modules in frost does not exceed this limit.

Can a battery be connected to the MIN TL-X2?

The X2 Pro version is battery ready, and it is the one to order if a storage battery is planned to be added later.

Does the MIN inverter have AFCI arc fault protection?

AFCI is supplied as an option. As standard, a Type II SPD is fitted on the DC side, which absorbs lightning surge overvoltages.

What is the maximum efficiency of the MIN TL-X/X2 inverters?

Up to 98.4 %. For comparison, off-grid SPF ES units have 93 %, so on a grid-tied roof without a battery the MIN loses noticeably less energy in conversion.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.