SUN2000-8/10K-LC0 single-phase hybrid inverter 8–10 kW
Country: China · Model: SUN2000-8/10K-LC0
A single-phase hybrid inverter of 8000 or 10 000 W AC with a recommended panel power of 12 000 and 15 000 W. It is designed for houses with a single-phase 220/230/240 V supply that need a large power reserve and whole-house backup.
- Rated AC power
- 8000 / 10 000 W
- Recommended PV power
- 12 000 / 15 000 W
- PV input
- 600 V, 3 MPPT, 40–560 V
- Max. / European efficiency
- 98.1% / 97.5%
Technical specifications
| Rated AC power | 8000 / 10 000 W |
|---|---|
| Recommended PV power | 12 000 / 15 000 W |
| PV input | 600 V, 3 MPPT, 40–560 V |
| Max. / European efficiency | 98.1% / 97.5% |
| Battery | 350–560 V, 25 A, charge/discharge 8–10 kW |
| Grid | 220/230/240 V, single-phase |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Three MPPT with a 40–560 V range and a maximum voltage of 600 V spread the panels over three roof slopes, and the low start-up threshold extends generation in the morning and evening. The battery input works in the 350–560 V range at 25 A and charges or discharges the battery at 8–10 kW, so the battery can cover the full rating of the inverter. Maximum efficiency is 98.1%, European efficiency 97.5%. For whole-house backup the inverter is combined with the SmartGuard-63A-S0 switch, which isolates the house from the grid during an outage. Such a set suits cottages with a heat pump, boiler and air conditioners on one phase.
How to choose
Between 8 and 10 kW, the choice depends on the peak load of the house and the panel area the roof can hold. If the house has a three-phase supply, it is better to take the SUN2000-5–12K-MAP0 with an unbalanced output and overload up to 200%. For larger three-phase systems with a battery there is the SUN2000-3–10KTL-M1, where backup goes through the BackupBox-B1 up to 3300 VA.
Request a price and lead time
SUN2000-8/10K-LC0 single-phase hybrid inverter 8–10 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How much panel power can be connected to the SUN2000-10K-LC0?
Up to 15 000 W of PV is recommended for the 10 kW version and up to 12 000 W for the 8 kW version.
What battery voltage is needed for the SUN2000-8K-LC0?
The battery input is rated for 350–560 V and 25 A, with charge and discharge power of 8–10 kW.
How to arrange whole-house backup with a single-phase hybrid inverter?
The SmartGuard-63A-S0 switch is needed, which transfers the house to power from the inverter and battery when the grid goes down.
How many MPPT does the SUN2000-8/10K-LC0 inverter have?
Three MPPT, with an operating range of 40–560 V and a maximum input voltage of 600 V.
What is the efficiency of the SUN2000-LC0 hybrid inverter?
Maximum efficiency is 98.1%, weighted European efficiency 97.5%.