Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

Sunny Tripower Hybrid X — 5–30 kW three-phase hybrid inverters

Sunny Tripower Hybrid X three-phase hybrid inverters cover 5–30 kW in two ranges, 5 to 15 kW and 20 to 30 kW, and work with the Storage M battery. They go into homes and small businesses, with optional whole-building backup.

Models
5 / 6 / 8 / 10 / 12 / 15 kW; 20 / 25 / 30 kW
MPPT
3 (5–15 kW), 4 (20–30 kW)
Min. PV input voltage
90 V (5–15 kW)
Parallel operation
up to 5 inverters

Technical specifications

Models5 / 6 / 8 / 10 / 12 / 15 kW; 20 / 25 / 30 kW
MPPT3 (5–15 kW), 4 (20–30 kW)
Min. PV input voltage90 V (5–15 kW)
Parallel operationup to 5 inverters
BatteryStorage M
Energy managementbuilt-in, Energy Maximizer
More from the manufacturer’s documentation
Type designationsSTPH5-60 / 6-60 / 8-60 / 10-60 / 12-60 / 15-60; STPH20-70 / 25-70 / 30-70
Integrated System Manager functionsbackup supply, dynamic purchase and feed-in tariffs, Section 14a EnWG, SG-Ready heat pumps
The manufacturer eCharger controlinverter firmware from 3.17.xx.R
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The smaller range is designated STPH5-60, 6-60, 8-60, 10-60, 12-60 and 15-60, and the larger one STPH20-70, 25-70 and 30-70. The 5, 6, 8, 10, 12 and 15 kW models have 3 MPPT inputs and start from 90 V PV input, so short strings on a small roof begin producing early in the morning. The 20, 25 and 30 kW models have 4 MPPT inputs, handy for roofs with several faces. Up to 5 inverters run in parallel. Energy management is built in through Energy Maximizer, so no separate energy manager is needed. The integrated System Manager runs backup supply, follows dynamic purchase and feed-in tariffs, applies Section 14a EnWG limits and drives an SG-Ready heat pump. From firmware 3.17.xx.R the inverter controls an eCharger charging station directly.

How to choose

For a private home the smaller 5–15 kW range is usually enough, while a shop, workshop or farm with three-phase load fits the 20–30 kW models. When one inverter is not enough, up to 5 run in parallel on one site. If no battery is planned, the array goes to a grid-tied Sunny Tripower 3.0–10.0 or a Sunny Tripower X 25 at 12–25 kW, and a single-phase supply takes the Sunny Boy 3.0–6.0.

Request a price and lead time

Sunny Tripower Hybrid X — 5–30 kW three-phase hybrid inverters. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many Sunny Tripower Hybrid X units can run in parallel?

Up to 5 inverters on one site.

What is the minimum PV voltage of the Sunny Tripower Hybrid X?

90 V on the 5–15 kW models.

How many MPPT inputs does the 30 kW Sunny Tripower Hybrid X have?

The 20–30 kW models have 4 MPPT inputs, and the 5–15 kW models have 3.

Which battery works with the Sunny Tripower Hybrid X?

The Storage M modular high-voltage battery, built up module by module in a tower.

Does the Sunny Tripower Hybrid X need a separate energy manager?

No, the built-in System Manager and Energy Maximizer handle the battery, tariffs, heat pump and eCharger.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.