ET LV three-phase hybrid inverter 5–20 kW for 48 V batteries
Country: · Model: ET LV
ET LV is a three-phase hybrid inverter of 5–20 kW for 48 V low-voltage batteries. It has 2, 3 or 4 MPPT inputs and two independent battery inputs with current up to 416 A. It is designed for a home with backup power.
- Power
- 5–20 kW
- MPPT
- 2 / 3 / 4
- Battery
- 48 V, two independent inputs up to 416 A
- Current per string
- 20 A
Technical specifications
| Power | 5–20 kW |
|---|---|
| MPPT | 2 / 3 / 4 |
| Battery | 48 V, two independent inputs up to 416 A |
| Current per string | 20 A |
| PV overload | 200 % |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The inverter works with low-voltage Lynx A G3/G4 and Lynx U G3 batteries and with 48 V batteries from other manufacturers. Two independent battery inputs accept current up to 416 A each within the declared value, so several battery racks are connected to it without an external combiner panel. The number of MPPT inputs is 2, 3 or 4, and the current per string is 20 A. PV overload reaches 200 %, which makes it possible to place on the roof an array larger than the inverter rating. For a private house this is a convenient option when batteries are already bought or an inexpensive 48 V rack is planned.
How to choose
The battery voltage decides here. For 48 V you need the ET LV rated 5–20 kW; for high-voltage racks take the ET PLUS+ rated 5–10 kW. If the site is commercial and the power is higher, see the ETR rated 50–125 kW or the ETC of 50 / 100 kW. The number of MPPT inputs is selected by the number of roof slopes.
Request a price and lead time
ET LV three-phase hybrid inverter 5–20 kW for 48 V batteries. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What battery does the ET LV need?
A low-voltage 48 V battery, for example Lynx A G3/G4 or Lynx U G3, as well as batteries from other manufacturers.
What is the power of the ET LV?
The range covers 5–20 kW. The current per string is 20 A.
How many MPPT inputs does the ET LV have?
Depending on the version, 2, 3 or 4.
What current do the ET LV battery inputs allow?
The two independent inputs are rated for current up to 416 A.
What PV overload does the ET LV allow?
200 %. The array on the roof can be twice as powerful as the inverter rating.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.