ET PLUS+ three-phase hybrid inverter 5–10 kW (HV)
Country: · Model: ET PLUS+
ET PLUS+ is a high-voltage hybrid inverter of 5–10 kW for a private house. It has 2 MPPT inputs, a maximum efficiency of 98.0–98.2 % and an IP66 enclosure. It manages loads and provides backup power when the grid goes down.
- Models
- GW5K / 6.5K / 8K / 10K-ET
- Max. efficiency
- 98.0–98.2 %
- MPPT
- 2
- Unbalanced output
- 100 %
Technical specifications
| Models | GW5K / 6.5K / 8K / 10K-ET |
|---|---|
| Max. efficiency | 98.0–98.2 % |
| MPPT | 2 |
| Unbalanced output | 100 % |
| Ingress protection | IP66 |
| Protection | Type II SPD on DC |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The inverter connects to a high-voltage battery and powers the house during a grid outage, and also distributes the load between consumers. The range consists of the GW5K, 6.5K, 8K and 10K-ET models. The output can be unbalanced, and each phase takes up to 100 % of rated power, so single-phase consumers do not limit operation. Two MPPT inputs accept arrays with different roof slope orientations. A type II SPD is installed on the DC side, and the IP66 enclosure can be hung on a facade or in a garage without an extra cabinet. For a house, this combination usually replaces a separate UPS. The models differ in power, while the design and the set of protections are the same.
How to choose
Choose the power by the peak load of the house and the PV area within 5–10 kW. If the battery is low-voltage, 48 V, and up to 20 kW is needed, take the ET LV. For a commercial site, the ETR rated 50–125 kW and the modular ETC of 50 / 100 kW are designed. If the house has a high-voltage battery and backup requirements are modest, a 5 kW inverter is usually enough for lighting, network equipment and a refrigerator.
Request a price and lead time
ET PLUS+ three-phase hybrid inverter 5–10 kW (HV). We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How many MPPT inputs does the ET PLUS+ have?
Two. Two roof slope directions are connected to the inverter separately, and each input tracks the maximum power point of its own array.
What is the maximum efficiency of the ET PLUS+?
Depending on the model, the efficiency is 98.0–98.2 %.
Is the ET PLUS+ protected against overvoltage on the PV side?
Yes, a type II SPD is installed on the DC side.
Can the ET PLUS+ phases be loaded unevenly?
Yes, an unbalanced output is allowed up to 100 %. Single-phase consumers do not reduce the power of the other phases.
What power ratings does the ET PLUS+ range have?
The GW5K, 6.5K, 8K and 10K-ET models, that is, from 5 to 10 kW.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.