ETR three-phase hybrid inverter 50–125 kW (HV)
Country: · Model: ETR
ETR is a three-phase hybrid inverter rated 50–125 kW with a high-voltage battery input. The PV array can be overloaded up to 200 %, and the enclosure is rated IP66. It suits commercial solar plants where storage is added later.
- Power
- 50–125 kW
- PV overload
- up to 200 %
- Input current
- 42 A
- Ingress protection
- IP66
Technical specifications
| Power | 50–125 kW |
|---|---|
| PV overload | up to 200 % |
| Input current | 42 A |
| Ingress protection | IP66 |
| Temperature | −35…+60 °C |
| Parallel operation | up to 15 units |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The inverter is designed for commercial sites where only the solar plant is built first and batteries are connected when energy storage becomes necessary. The input current is 42 A and PV-side overload is allowed up to 200 %, so the generation can be sized with a reserve for peak hours. The IP66 enclosure stands outdoors without an extra cabinet, and the operating range of −35…+60 °C covers both winter frost and summer heating on a roof. Up to 15 units run in parallel, so plant capacity is increased by adding inverters rather than replacing equipment.
How to choose
The deciding parameters here are the power of 50–125 kW and the number of units in parallel, up to 15. For a house, look at the ET PLUS+ (5–10 kW) or the ET LV (5–20 kW) with a 48 V battery. If you need a modular cabinet of 50 / 100 kW with Lynx C batteries, there is the ETC, and for retrofitting an existing solar plant on the AC side there is the BTC.
Request a price and lead time
ETR three-phase hybrid inverter 50–125 kW (HV). We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the power of the ETR inverter?
The range is 50–125 kW depending on the version. The input current is 42 A.
Where can the ETR be installed and what is its protection rating?
The enclosure is rated IP66, so dust and water jets do no harm, and the inverter is mounted outdoors. The operating temperature is −35…+60 °C.
How many ETR inverters can be connected in parallel?
Up to 15 units work in parallel, which makes it possible to expand the plant in stages.
Can batteries be added to the ETR after the solar plant is launched?
Yes, the inverter is ready for storage. The solar plant is built first and batteries are connected later, when the budget allows.
What PV overload does the ETR allow?
Up to 200 %. In practice this means the array can be built above the inverter's rated power.