ETR three-phase hybrid inverter 50–125 kW (HV)

ETR is a three-phase hybrid inverter rated 50–125 kW with a high-voltage battery input. The PV array can be overloaded up to 200 %, and the enclosure is rated IP66. It suits commercial solar plants where storage is added later.

Power
50–125 kW
PV overload
up to 200 %
Input current
42 A
Ingress protection
IP66

Technical specifications

Power50–125 kW
PV overloadup to 200 %
Input current42 A
Ingress protectionIP66
Temperature−35…+60 °C
Parallel operationup to 15 units

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The inverter is designed for commercial sites where only the solar plant is built first and batteries are connected when energy storage becomes necessary. The input current is 42 A and PV-side overload is allowed up to 200 %, so the generation can be sized with a reserve for peak hours. The IP66 enclosure stands outdoors without an extra cabinet, and the operating range of −35…+60 °C covers both winter frost and summer heating on a roof. Up to 15 units run in parallel, so plant capacity is increased by adding inverters rather than replacing equipment.

How to choose

The deciding parameters here are the power of 50–125 kW and the number of units in parallel, up to 15. For a house, look at the ET PLUS+ (5–10 kW) or the ET LV (5–20 kW) with a 48 V battery. If you need a modular cabinet of 50 / 100 kW with Lynx C batteries, there is the ETC, and for retrofitting an existing solar plant on the AC side there is the BTC.

Request a price and lead time

ETR three-phase hybrid inverter 50–125 kW (HV). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power of the ETR inverter?

The range is 50–125 kW depending on the version. The input current is 42 A.

Where can the ETR be installed and what is its protection rating?

The enclosure is rated IP66, so dust and water jets do no harm, and the inverter is mounted outdoors. The operating temperature is −35…+60 °C.

How many ETR inverters can be connected in parallel?

Up to 15 units work in parallel, which makes it possible to expand the plant in stages.

Can batteries be added to the ETR after the solar plant is launched?

Yes, the inverter is ready for storage. The solar plant is built first and batteries are connected later, when the budget allows.

What PV overload does the ETR allow?

Up to 200 %. In practice this means the array can be built above the inverter's rated power.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.