Symo GEN24 / Symo GEN24 Plus — three-phase hybrid solar inverter 3–12 kW

The Symo GEN24 three-phase hybrid inverter covers 3, 4, 5, 6, 8 and 12 kW ratings for a 230/400 V grid. It is used in homes and small facilities, and the Plus version works with a battery.

Grid
3 phases, 230/400 V
Power
3 / 4 / 5 kW; 6 / 8 / 12 kW
MPP trackers
2
DC input voltage
80–1,000 V

Technical specifications

Grid3 phases, 230/400 V
Power3 / 4 / 5 kW; 6 / 8 / 12 kW
MPP trackers2
DC input voltage80–1,000 V
Ingress protectionIP66
Dimensions (W×H×D)474×530×165 mm (3–5 kW); 529×595×180 mm (6–12 kW)
Backup powerPV Point; Full Backup on the Plus version with battery (except Symo GEN24 3.0–5.0 Plus)
ProtectionArc Guard (AFCI) in the SC generation, active cooling
More from the manufacturer’s documentation
Rated input voltage610 V
Feed-in start voltage80 V
Usable MPP voltage range80–800 V
MPP voltage range at rated power125–800 V (3.0); 170–800 V (4.0); 210–800 V (5.0); 174–800 V (6.0); 224–800 V (8.0); 278–800 V (10.0)
Max. input current12.5 / 12.5 A (3.0–5.0); 25 / 12.5 A (6.0–10.0, MPPT1 / MPPT2)
Max. PV short-circuit current20 / 20 A (3.0–5.0); 40 / 20 A (6.0–10.0, MPPT1 / MPPT2)
Max. PV generator power4,500 / 6,000 / 7,500 / 9,000 / 12,000 / 15,000 Wp (3.0 / 4.0 / 5.0 / 6.0 / 8.0 / 10.0)
Rated AC output current (400 V)4.3 / 5.8 / 7.2 / 8.7 / 11.6 / 14.5 A (3.0 / 4.0 / 5.0 / 6.0 / 8.0 / 10.0)
Grid voltage tolerance3~ NPE 400/230 or 380/220 V (+20 % / −30 %); 50 / 60 Hz (45–65 Hz)
Power factor / harmonicscos φ 0.7–1 ind. / cap.; THD < 3 %
PV Point3,000 VA; 1~ NPE 220/230 V; switchover ~15 s
Full Backup (GEN24 Plus 6.0–10.0)6,000 / 8,000 / 10,000 VA; 3.68 kVA per phase; switchover ~10 s; external switchover components required
Battery input (GEN24 Plus)1 input; 160–700 V; max. current 12.5 A (3.0–5.0) / 22 A (6.0–10.0); push-in spring terminals 2.5–10 mm²
Max. DC charge/discharge power3,150 / 4,180 / 5,200 / 6,220 / 8,260 / 10,300 W (3.0 / 4.0 / 5.0 / 6.0 / 8.0 / 10.0)
Compatible batteriesReserva, Battery-Box Premium HVS/HVM, LG FLEX
Max. efficiency98.1 % (3.0); 98.2 % (4.0–10.0)
European efficiency (ηEU)96.7 / 97.2 / 97.5 / 97.7 / 97.8 / 97.9 % (3.0 / 4.0 / 5.0 / 6.0 / 8.0 / 10.0)
MPP adaptation efficiency> 99.9 %
Weight (inverter / packed)15.6 / 19.4 kg (3.0–5.0); 23.4 / 28.5 kg (6.0–10.0)
Operating temperature−25 to +60 °C
Permissible humidity0–100 %
Noise emission< 36 dB(A) (3.0–5.0); < 47 dB(A) (6.0–10.0)
Night-time consumption< 10 W
Max. altitude3,000 m (unrestricted) / 4,000 m (restricted voltage range)
ConnectionPV: 3 × DC+ and 3 × DC− push-in spring terminals 2.5–10 mm²; AC: 5-pin push-in terminals 1.5–10 mm²; backup: 3-pin 1.5–10 mm²
Built-in protection devicesDC insulation monitoring, DC disconnector, reverse polarity protection; protection class I; overvoltage category DC/AC 2/3
InterfacesWLAN / 2 × Ethernet LAN; 2 × RS485 (Modbus RTU SunSpec, Smart Meter, battery, Ohmpilot); 6 digital inputs + 6 digital I/Os; WSD; Modbus TCP SunSpec, Solar API (JSON); datalogger and web server
StandardsIEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126, VDE AR-N 4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G98/G99, R25
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The Dynamic Peak Manager function keeps the yield up when modules are partly shaded. Two MPP trackers work over an 80–1,000 V input range, feed-in starts as low as 80 V, and strings land on 2.5–10 mm² push-in terminals. Open interfaces accept third-party components, with a meter, a battery and an Ohmpilot controller wired over RS485 and data passed to SCADA over Modbus TCP SunSpec. The 3–5 kW models come in a 474×530×165 mm housing and the 6–12 kW models in a 529×595×180 mm housing (W×H×D), both rated IP66. Every version has the 3,000 VA PV Point output, and Full Backup with a battery is available on the Plus versions except Symo GEN24 3.0–5.0 Plus. The SC generation carries Arc Guard (AFCI) protection, and cooling is active.

How to choose

Pick the rating by array and battery. The smaller models take up to 12.5 A per tracker while the larger ones carry 25 A on MPPT1, so parallel strings of high-power modules belong on the 6–12 kW units. If the site needs full three-phase backup, take a Plus from 6 kW, where Full Backup gives 3.68 kVA per phase. With a single-phase supply the Primo GEN24 fits, and for 15–33.3 kW with a battery the Verto Plus is needed.

Request a price and lead time

Symo GEN24 / Symo GEN24 Plus — three-phase hybrid solar inverter 3–12 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the input voltage range of Symo GEN24?

80–1,000 V DC across 2 MPP trackers.

Do all Symo GEN24 Plus models support Full Backup?

No, Symo GEN24 3.0–5.0 Plus has no Full Backup. The other Plus versions support it with a battery.

What are the dimensions of the Symo GEN24 6–12 kW?

529×595×180 mm (W×H×D), while the 3–5 kW models measure 474×530×165 mm.

Which batteries work with Symo GEN24 Plus?

Reserva, Battery-Box HVS/HVM and LG FLEX. The battery input accepts 160–700 V.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.