Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

Verto Plus — three-phase hybrid inverter 15–33.3 kW

Rated 15–33.3 kW, the Verto Plus three-phase hybrid inverter charges or discharges a battery at up to 28.3 kW when paired with Reserva Pro. It targets commercial and agricultural sites that need backup for the full load.

Power
15 / 17.5 / 20 / 25 / 30 / 33.3 kW
MPP trackers
3 (6 DC inputs)
MPPT range
150–870 V
Max. DC voltage
1,000 V

Technical specifications

Power15 / 17.5 / 20 / 25 / 30 / 33.3 kW
MPP trackers3 (6 DC inputs)
MPPT range150–870 V
Max. DC voltage1,000 V
Ingress protectionIP66
Backup powerthree-phase Full Backup; Backup Power Boost up to 50 kVA peak power
Battery charge/dischargeup to 28.3 kW (with Reserva Pro)
ProtectionDC SPD type 1+2, AC type 2, AFCI
More from the manufacturer’s documentation
Nominal input voltage600 V
DC input voltage range150–1,000 V
Feed-in start voltage150 V
MPP voltage range at full power210–870 V (15.0); 245–870 V (17.5); 275–870 V (20.0); 350–870 V (25.0); 400–870 V (30.0); 410–870 V (33.3)
Max. input / short-circuit current28 A per MPPT; short circuit 50 A per MPPT, 150 A per inverter
Max. PV generator power22,500 / 26,250 / 30,000 / 37,500 / 45,000 / 50,000 Wp (15.0 / 17.5 / 20.0 / 25.0 / 30.0 / 33.3)
Rated AC output current (400 V)21.7 / 25.4 / 29.0 / 36.2 / 43.5 / 48.3 A (15.0 / 17.5 / 20.0 / 25.0 / 30.0 / 33.3)
Grid connection3~ (N)PE 380/220 or 400/230 V; 50 / 60 Hz (45–65 Hz); cos φ 0–1 ind. / cap.
Total harmonic distortion< 3 % (15.0–25.0); < 1 % (30.0, 33.3)
Full Backup peak power (max. 10 s)30,000 VA (15.0–20.0); 50,000 VA (25.0–33.3)
Full Backup power per phase7,000 / 7,300 VA at 380 / 400 V (15.0–20.0); 11,100 VA (25.0–33.3)
Supported phase asymmetry, Full Backup25.0 / 32.0 A peak (15.0–20.0); 50.0 / 72.5 A peak (25.0–33.3)
Backup switchover time~11 s (external switchover components required)
Battery input1 input; 150–700 V; max. charge/discharge current 50 A; Stäubli MC4 Evo Stor connectors
Compatible batteriesReserva, Reserva Pro, Battery-Box HVM, HVS, HVM+, HVS+, HVB
Max. efficiency98.03–98.16 %
European efficiency (ηEU)97.35–97.96 %
MPP adaptation efficiency> 99.9 %
Dimensions (H × W × D)865 × 574 × 279 mm
Weight43 kg
Coolingregulated air cooling
Operating temperature−25 to +60 °C
Permissible humidity0–100 %
Noise emission< 50.3 dB(A) (15.0–20.0); < 56.7 dB(A) (25.0–33.3)
Installationindoor and outdoor, 90°–10° tilt; max. altitude 3,000 / 4,000 m; protection class I; overvoltage category DC/AC 2/3; night-time consumption < 16 W
AC connection4–35 mm² (Al and Cu); M32 cable gland (Ø 12–24.5 mm), optional M50 (Ø 10–35 mm)
Built-in protection devicesDC insulation monitoring, DC disconnector, RCMU, reverse polarity protection, power limitation on overload
InterfacesWLAN 802.11b/g; Ethernet LAN RJ45 (10/100 Mbit/s, up to 100 m); 2 × RS485 (Modbus RTU SunSpec / Smart Meter / battery); 6 digital inputs + 6 digital I/Os; WSD; Modbus TCP SunSpec, JSON; datalogger and web server
StandardsIEC 62109-1/-2, VDE-AR-N 4105:2018, VDE-AR-N 4110:2023-09, EN 50549-1/-2, CEI 0-16, CEI 0-21, UNE 217002:2020, IEC 62116, IEC 61727, AS/NZS 4777.2:2020+A1, IEC 63027:2023, G99
Country of manufactureAustria
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Ratings are 15, 17.5, 20, 25, 30 and 33.3 kW. With a battery and a grid disconnect device, the inverter moves the whole site to three-phase Full Backup in about 11 s and can perform a black start. Backup Power Boost delivers up to 50 kVA of peak power for up to 10 s, enough to start pump and compressor motors. Phase imbalance is tolerated in backup mode, up to 50.0 / 72.5 A peak on the larger models. Three MPP trackers with 6 DC inputs work over 150–870 V with a 1,000 V maximum. The battery connects to a single 150–700 V input at up to 50 A. Protection includes a type 1+2 DC SPD, a type 2 AC SPD and AFCI, in an IP66 housing of 865 × 574 × 279 mm weighing 43 kg.

How to choose

Size the unit first by the starting currents of the backed-up load and only then by array power. The 15.0–20.0 models give up to 30,000 VA peak and 7,300 VA per phase at 400 V in backup, while the 25.0–33.3 models hold 50,000 VA and 11,100 VA per phase. If no backup is needed, the grid-tied Verto covers the same power band without a battery input. A house with a three-phase supply up to 12 kW is served by the Symo GEN24 Plus.

Request a price and lead time

Verto Plus — three-phase hybrid inverter 15–33.3 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What battery charging power does Verto Plus have?

Up to 28.3 kW for charge and discharge with Reserva Pro.

Does Verto Plus support black start?

Yes, with a battery and a grid disconnect device it starts the site without the grid and holds three-phase Full Backup with peaks up to 50 kVA.

How many MPPTs does the Verto Plus hybrid inverter have?

3 MPP trackers with 6 DC inputs, range 150–870 V.

Which batteries are compatible with Verto Plus?

Reserva and Reserva Pro, plus Battery-Box HVM, HVS, HVM+, HVS+ and HVB. Battery voltage must sit within 150–700 V.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.