Verto Plus — three-phase hybrid inverter 15–33.3 kW
Country: Austria · Model: Verto Plus
Rated 15–33.3 kW, the Verto Plus three-phase hybrid inverter charges or discharges a battery at up to 28.3 kW when paired with Reserva Pro. It targets commercial and agricultural sites that need backup for the full load.
- Power
- 15 / 17.5 / 20 / 25 / 30 / 33.3 kW
- MPP trackers
- 3 (6 DC inputs)
- MPPT range
- 150–870 V
- Max. DC voltage
- 1,000 V
Technical specifications
| Power | 15 / 17.5 / 20 / 25 / 30 / 33.3 kW |
|---|---|
| MPP trackers | 3 (6 DC inputs) |
| MPPT range | 150–870 V |
| Max. DC voltage | 1,000 V |
| Ingress protection | IP66 |
| Backup power | three-phase Full Backup; Backup Power Boost up to 50 kVA peak power |
| Battery charge/discharge | up to 28.3 kW (with Reserva Pro) |
| Protection | DC SPD type 1+2, AC type 2, AFCI |
| More from the manufacturer’s documentation | |
| Nominal input voltage | 600 V |
| DC input voltage range | 150–1,000 V |
| Feed-in start voltage | 150 V |
| MPP voltage range at full power | 210–870 V (15.0); 245–870 V (17.5); 275–870 V (20.0); 350–870 V (25.0); 400–870 V (30.0); 410–870 V (33.3) |
| Max. input / short-circuit current | 28 A per MPPT; short circuit 50 A per MPPT, 150 A per inverter |
| Max. PV generator power | 22,500 / 26,250 / 30,000 / 37,500 / 45,000 / 50,000 Wp (15.0 / 17.5 / 20.0 / 25.0 / 30.0 / 33.3) |
| Rated AC output current (400 V) | 21.7 / 25.4 / 29.0 / 36.2 / 43.5 / 48.3 A (15.0 / 17.5 / 20.0 / 25.0 / 30.0 / 33.3) |
| Grid connection | 3~ (N)PE 380/220 or 400/230 V; 50 / 60 Hz (45–65 Hz); cos φ 0–1 ind. / cap. |
| Total harmonic distortion | < 3 % (15.0–25.0); < 1 % (30.0, 33.3) |
| Full Backup peak power (max. 10 s) | 30,000 VA (15.0–20.0); 50,000 VA (25.0–33.3) |
| Full Backup power per phase | 7,000 / 7,300 VA at 380 / 400 V (15.0–20.0); 11,100 VA (25.0–33.3) |
| Supported phase asymmetry, Full Backup | 25.0 / 32.0 A peak (15.0–20.0); 50.0 / 72.5 A peak (25.0–33.3) |
| Backup switchover time | ~11 s (external switchover components required) |
| Battery input | 1 input; 150–700 V; max. charge/discharge current 50 A; Stäubli MC4 Evo Stor connectors |
| Compatible batteries | Reserva, Reserva Pro, Battery-Box HVM, HVS, HVM+, HVS+, HVB |
| Max. efficiency | 98.03–98.16 % |
| European efficiency (ηEU) | 97.35–97.96 % |
| MPP adaptation efficiency | > 99.9 % |
| Dimensions (H × W × D) | 865 × 574 × 279 mm |
| Weight | 43 kg |
| Cooling | regulated air cooling |
| Operating temperature | −25 to +60 °C |
| Permissible humidity | 0–100 % |
| Noise emission | < 50.3 dB(A) (15.0–20.0); < 56.7 dB(A) (25.0–33.3) |
| Installation | indoor and outdoor, 90°–10° tilt; max. altitude 3,000 / 4,000 m; protection class I; overvoltage category DC/AC 2/3; night-time consumption < 16 W |
| AC connection | 4–35 mm² (Al and Cu); M32 cable gland (Ø 12–24.5 mm), optional M50 (Ø 10–35 mm) |
| Built-in protection devices | DC insulation monitoring, DC disconnector, RCMU, reverse polarity protection, power limitation on overload |
| Interfaces | WLAN 802.11b/g; Ethernet LAN RJ45 (10/100 Mbit/s, up to 100 m); 2 × RS485 (Modbus RTU SunSpec / Smart Meter / battery); 6 digital inputs + 6 digital I/Os; WSD; Modbus TCP SunSpec, JSON; datalogger and web server |
| Standards | IEC 62109-1/-2, VDE-AR-N 4105:2018, VDE-AR-N 4110:2023-09, EN 50549-1/-2, CEI 0-16, CEI 0-21, UNE 217002:2020, IEC 62116, IEC 61727, AS/NZS 4777.2:2020+A1, IEC 63027:2023, G99 |
| Country of manufacture | Austria |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504408800 (>7.5 kVA) |
| CN code (EU) | 85044084 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Ratings are 15, 17.5, 20, 25, 30 and 33.3 kW. With a battery and a grid disconnect device, the inverter moves the whole site to three-phase Full Backup in about 11 s and can perform a black start. Backup Power Boost delivers up to 50 kVA of peak power for up to 10 s, enough to start pump and compressor motors. Phase imbalance is tolerated in backup mode, up to 50.0 / 72.5 A peak on the larger models. Three MPP trackers with 6 DC inputs work over 150–870 V with a 1,000 V maximum. The battery connects to a single 150–700 V input at up to 50 A. Protection includes a type 1+2 DC SPD, a type 2 AC SPD and AFCI, in an IP66 housing of 865 × 574 × 279 mm weighing 43 kg.
How to choose
Size the unit first by the starting currents of the backed-up load and only then by array power. The 15.0–20.0 models give up to 30,000 VA peak and 7,300 VA per phase at 400 V in backup, while the 25.0–33.3 models hold 50,000 VA and 11,100 VA per phase. If no backup is needed, the grid-tied Verto covers the same power band without a battery input. A house with a three-phase supply up to 12 kW is served by the Symo GEN24 Plus.
Request a price and lead time
Verto Plus — three-phase hybrid inverter 15–33.3 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What battery charging power does Verto Plus have?
Up to 28.3 kW for charge and discharge with Reserva Pro.
Does Verto Plus support black start?
Yes, with a battery and a grid disconnect device it starts the site without the grid and holds three-phase Full Backup with peaks up to 50 kVA.
How many MPPTs does the Verto Plus hybrid inverter have?
3 MPP trackers with 6 DC inputs, range 150–870 V.
Which batteries are compatible with Verto Plus?
Reserva and Reserva Pro, plus Battery-Box HVM, HVS, HVM+, HVS+ and HVB. Battery voltage must sit within 150–700 V.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.