X3-HYBRID G4 — three-phase hybrid inverter 5–15 kW
Country: China · Model: X3-HYBRID G4
The X3-HYBRID G4 three-phase hybrid inverter comes in 5, 6, 8, 10, 12 and 15 kW versions and works with a high-voltage battery. It is installed in private houses and small business sites where the PV plant, the storage and the grid must operate as one system.
- Power
- 5 / 6 / 8 / 10 / 12 / 15 kW
- MPPT
- 2, up to 28 A per tracker
- MPPT range
- 180–950 V
- EPS peak power
- up to 22.5 kVA, 10 s
Technical specifications
| Power | 5 / 6 / 8 / 10 / 12 / 15 kW |
|---|---|
| MPPT | 2, up to 28 A per tracker |
| MPPT range | 180–950 V |
| EPS peak power | up to 22.5 kVA, 10 s |
| Switchover | < 10 ms |
| Ingress protection | IP65 |
| Parallel operation | up to 150 kW |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA) |
| CN code (EU) | 85044084 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The output is asymmetric, so each phase can deliver up to 5 kW on its own, and a powerful single-phase load does not limit the other two lines. The two MPPT inputs accept up to 28 A per tracker, so modules with a higher operating current can be connected. The 180–950 V operating range fits long strings with a margin for the open-circuit voltage in frost. In EPS mode the inverter holds up to 22.5 kVA for 10 s, which is enough to start a pump or a compressor. The changeover to backup power takes less than 10 ms, so computers and boilers do not restart. The IP65 enclosure can be mounted on an outside wall under a canopy. The unit is ready for VPP operation, where an aggregator controls charging and discharging of the storage on a grid signal.
How to choose
The rating is chosen by the peak load of the house and the power of the module array. If one unit is not enough, several inverters are connected in parallel up to 150 kW in total. For a grid-only PV plant of 40–60 kW without a battery the X3-MEGA G2 is more suitable, and for a small roof or balcony with a few panels the X1-Micro microinverters of 750–2400 W are enough.
Request a price and lead time
X3-HYBRID G4 — three-phase hybrid inverter 5–15 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How many kW per phase can the X3-HYBRID G4 deliver under an unbalanced load?
Up to 5 kW on each phase separately. This matters for houses where a boiler, a stove or a pump is connected to one phase.
What is the peak power of the X3-HYBRID G4 in EPS backup mode?
Up to 22.5 kVA for 10 s. This reserve covers the starting currents of pump and compressor motors.
What string voltage is permitted for the X3-HYBRID G4?
The MPPT range is 180–950 V, with 2 trackers and a current of up to 28 A each. The number of modules in a string is calculated from the minimum temperature of the site.
Can several X3-HYBRID G4 units be connected in parallel?
Yes, parallel operation is supported up to a total of 150 kW, which suits a small enterprise.
How fast does the X3-HYBRID G4 switch to the battery when the grid fails?
In less than 10 ms, so household and office equipment keeps running without a restart.