SUN-SG HP3 — three-phase hybrid inverters 5–50 kW for high-voltage batteries

High-voltage three-phase hybrid inverters rated from 5 to 50 kW. They work in houses and at commercial and small industrial sites where a solar plant, a storage unit and a backup generator are installed together.

Power
5–25 kW (SG01HP3-AM2), 5–12, 15–25, 25–30 kW (SG02HP3), 29.9–50 kW (SG01HP3-BM3/BM4)
Battery voltage
160–700 V (5–25 kW), 160–800 V (29.9–50 kW)
Charge/discharge current
up to 50 A; 50+50 A (2 battery inputs)
Parallel operation
up to 10 units

Technical specifications

Power5–25 kW (SG01HP3-AM2), 5–12, 15–25, 25–30 kW (SG02HP3), 29.9–50 kW (SG01HP3-BM3/BM4)
Battery voltage160–700 V (5–25 kW), 160–800 V (29.9–50 kW)
Charge/discharge currentup to 50 A; 50+50 A (2 battery inputs)
Parallel operationup to 10 units
Unbalanced output100 %
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The range consists of three series: the SG01HP3-AM2 rated 5–25 kW, the SG02HP3 rated 5–12, 15–25 and 25–30 kW and the SG01HP3-BM3/BM4 rated 29.9–50 kW. For the 5–25 kW models the battery voltage range is 160–700 V, and for 29.9–50 kW it is extended to 160–800 V. High battery voltage reduces the current in the cables, so even at high power a charge and discharge current of up to 50 A is sufficient. Some models have 2 battery inputs of 50 A each, to which two independent battery racks are connected. The output withstands 100 % unbalanced load, and a generator is connected to the inverter and supports the system during long outages. Up to 10 inverters can be connected in parallel.

How to choose

First find out the battery voltage offered by the storage supplier and check whether it falls within 160–700 V or 160–800 V. Then look at the power: up to 30 kW the SG02HP3 or SG01HP3-AM2 is suitable, and from 29.9 kW the BM3/BM4 series is needed. For low-voltage batteries it is more correct to take the SUN-SG LP3 series, and for a house without a grid the off-grid SUN-OG03LP1 rated 3–8.8 kW is enough.

Request a price and lead time

SUN-SG HP3 — three-phase hybrid inverters 5–50 kW for high-voltage batteries. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What battery voltage is needed for the SUN-SG HP3 inverter?

160–700 V for the 5–25 kW models and 160–800 V for the 29.9–50 kW models.

Can two battery racks be connected to one hybrid inverter?

Yes, on models with 2 battery inputs each input accepts current of up to 50 A.

How many high-voltage hybrid inverters can be connected in parallel?

Up to 10 units, so systems of hundreds of kilowatts are built on the basis of the series.

Does the SUN-SG HP3 hybrid inverter work with a generator?

Yes, a generator is connected to the inverter, and it supplies the load and charges the 160–800 V battery during long outages.

Can the phases be loaded unevenly?

Yes, the output is rated for 100 % unbalanced load, which is important for houses with many single-phase consumers.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.