Sunny Tripower X 25 — 12–25 kW three-phase grid-tied inverter

The Sunny Tripower X three-phase grid-tied range covers 12, 15, 20 and 25 kW. These units serve commercial sites and large residential PV plants, handle active and reactive power control on their own and connect to the grid under VDE-AR-N 4105.

Models
12 / 15 / 20 / 25 kW
System manager
up to 5 inverters, max. 135 kVA
Functions
ShadeFix, ArcFix, Dynamic Power Control
Standards
VDE-AR-N 4105

Technical specifications

Models12 / 15 / 20 / 25 kW
System managerup to 5 inverters, max. 135 kVA
FunctionsShadeFix, ArcFix, Dynamic Power Control
StandardsVDE-AR-N 4105
More from the manufacturer’s documentation
Type designationsSTP 15-50 / STP 20-50 / STP 25-50
Integrated AC interface switchreplaces an external central switch per VDE-AR-N 4105:2018-11, ch. 6.4.1, method C (30–135 kW plants)
AC interface switch turn-off time≤ 100 ms
Interface switch self-testbefore each switch-on and daily
Min. firmware for the function02.02.07.R
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The built-in system manager links up to 5 inverters with a combined maximum of 135 kVA, so no separate plant controller is needed. ShadeFix adjusts maximum power point tracking under partial shading, and ArcFix opens the circuit on an electric arc. Dynamic Power Control caps grid feed-in at a set value, as export-limited connection agreements require. An integrated grid disconnector replaces the external central one under VDE-AR-N 4105:2018-11, section 6.4.1, method C for installations of 30–135 kW. It opens the AC side in no more than 100 ms and tests itself before every start and once a day. The function needs firmware 02.02.07.R or later, so check the version at commissioning.

How to choose

Choose the rating by array size and the site connection, with type designations STP 15-50, STP 20-50 and STP 25-50 in the documentation. No external grid protection cabinet is needed once the installation falls into the 30–135 kW window, from two X 25 units up to five under one manager. A 50–60 kW site in a single unit fits the Sunny Tripower X 60 as STP 50-80 or STP 60-80. A house with a single-phase supply is covered by the Sunny Boy 3.0–6.0.

Request a price and lead time

Sunny Tripower X 25 — 12–25 kW three-phase grid-tied inverter. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many inverters can the Sunny Tripower X system manager control?

Up to 5 inverters with a combined maximum of 135 kVA, with the manager running inside one of them.

Which power ratings are available in the Sunny Tripower X 25 series?

Models rated 12, 15, 20 and 25 kW, all three-phase.

Does the Sunny Tripower X comply with VDE-AR-N 4105?

Yes, it is built to VDE-AR-N 4105, and its integrated disconnector follows the 2018-11 edition.

Does the Sunny Tripower X need an external grid protection cabinet?

Not for installations of 30–135 kW, since the integrated disconnector replaces the central one under method C and trips within 100 ms.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.