Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

Sunny Tripower X 60 — 50–60 kW three-phase grid-tied inverter

The Sunny Tripower X comes in two versions, STP 50-80 and STP 60-80, rated 50 and 60 kW, each with 5 MPPT inputs. This three-phase grid-tied inverter targets mid-size commercial PV plants on warehouse and factory roofs, where the plant is built from several units.

Models
STP 50-80, STP 60-80
Power
up to 60 kW
MPPT
5
Weight
50.5 kg

Technical specifications

ModelsSTP 50-80, STP 60-80
Powerup to 60 kW
MPPT5
Weight50.5 kg
Mountingwall, optionally horizontal on the roof
More from the manufacturer’s documentation
Max. PV array power75,000 Wp (STP 50-80) / 90,000 Wp (STP 60-80)
Max. input voltage1,000 V
MPP voltage range500–850 V at rated power; operating 200–850 V
Rated input voltage630 V
Min. / start voltage200 / 250 V
Max. input current per MPPT / per string40 / 22 A
Short-circuit current per MPPT / per string50 / 30 A
Strings per MPPT2
Nominal AC voltage230 / 400 V; range 180–305 V
Grid frequency50 Hz (45–65 Hz)
Rated / max. output current72.5 / 79.5 A (STP 50-80); 86.6 / 95.3 A (STP 60-80)
Power factor1; adjustable 0.8 overexcited to 0.8 underexcited
Total harmonic distortion< 3%
Max. / European efficiency98.1 / 97.7% (STP 50-80); 98.1 / 97.8% (STP 60-80)
Dimensions (W × H × D)680 × 717.5 × 332 mm
Operating temperature−25 °C to +60 °C
Noise emission63 dB(A)
Self-consumption at night< 15 W
Topology / coolingno galvanic isolation / OptiCool
Degree of protectionIP65
DC / AC connectionSUNCLIX / terminal lug up to 70 mm²
InterfacesEthernet (2 ports), Wi-Fi (10 m range); Modbus, SunSpec Modbus, Speedwire
ProtectionAFCI per IEC 63027, DC type I + II / AC type II surge arresters, all-pole residual-current monitoring
Control inputs4 digital inputs for power limitation, 2 for fast stop; multifunction relay
System Managerup to 5 subordinate devices, up to 135 kVA in total
Warranty5 years (optional 10 / 15 / 20 years)
StandardsVDE-AR-N 4105:2018 / 4110:2023 / 4120:2020, EN 50549-1/-2:2018, EN 50549-10:2022, IEC 62109-1/-2, IEC 62116, IEC 61727, CEI 0-21 / CEI 0-16, EREC G99/2:2025
CybersecurityEN 18031-1 (RED), ETSI EN 303 645, Speedwire Encrypted Communication (SEC), ISO 27001 cloud
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The system manager is built into the inverter and handles plant control and grid feed-in for up to 5 devices totaling 135 kVA. DC cables connect without tools on SUNCLIX plugs, 2 strings per tracker and up to 22 A per string. Five trackers give flexibility when laying out strings across several roof faces. The unit weighs 50.5 kg and mounts on a wall, or optionally lies flat on the roof. The IP65 enclosure with OptiCool runs from −25 to +60 °C. AC lands on lugs up to 70 mm², with rated current of 72.5 A for the STP 50-80 and 86.6 A for the STP 60-80. Arc-fault detection to IEC 63027, type I + II DC surge arresters and residual current monitoring are inside.

How to choose

The array size decides between versions, up to 75,000 Wp for the STP 50-80 and 90,000 Wp for the STP 60-80. Size the breaker and feeder for a maximum current of 79.5 and 95.3 A respectively. A smaller roof is covered by the Sunny Tripower X 25 in 12–25 kW models. When 135 kVA under one manager is not enough, move up to the Sunny Tripower 125 (STP125-70) with 12 MPPT.

Request a price and lead time

Sunny Tripower X 60 — 50–60 kW three-phase grid-tied inverter. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How much does the Sunny Tripower X 60 weigh?

It weighs 50.5 kg at 680 × 717.5 × 332 mm, light because the design has no galvanic isolation.

How many MPPT inputs does the 60 kW Sunny Tripower X have?

It has 5 MPPT inputs with 2 strings each and up to 40 A per tracker.

Can the Sunny Tripower X 60 be mounted horizontally on a roof?

Yes, besides wall mounting it can optionally lie horizontally on a roof. The IP65 enclosure withstands rain and dust.

What DC voltage does the Sunny Tripower X 60 accept?

Up to 1,000 V, with full power inside the 500–850 V MPP window. It starts at 250 V.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.