EQUINOX2 T / T-RV — three-phase grid-tied solar inverters 4–100 kW
Country: Spain · Model: EQUINOX2 T / T-RV
The three-phase grid-tied inverters EQUINOX2 T / T-RV cover powers from 4 to 100 kW. They are installed at commercial and industrial solar plants, from a shop roof to a factory roof.
- Power
- 4–100 kW
- Technology
- SiC
- Display
- OLED
- Monitoring
- EQUINOX portal and app
Technical specifications
| Power | 4–100 kW |
|---|---|
| Technology | SiC |
| Display | OLED |
| Monitoring | EQUINOX portal and app |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Power switches on silicon carbide (SiC) have lower switching losses, which reduces heating and heatsink size. Three-phase connection distributes the generation evenly across the phases, so at sites with a three-phase input there is no imbalance typical for several single-phase inverters. The OLED display on the case shows the mode and current power, which is convenient during commissioning without a phone. Operating data is sent to the EQUINOX portal and app, where the generation of each inverter of the plant can be seen. At large plants several inverters are connected in parallel on the AC side, dividing the panel field into groups.
How to choose
The total power of the plant is divided between inverters so that each works closer to its rating. For a small business models of several tens of kilowatts are enough, and for a factory the larger ones are taken, up to 100 kW per unit. If the input is single-phase and the power is up to 10 kW, the EQUINOX2 S/SX is more suitable. For self-consumption with a battery and operation during a grid outage, the hybrid HT of 4–12 kW or HT+ of 15–50 kW are selected.
Request a price and lead time
EQUINOX2 T / T-RV — three-phase grid-tied solar inverters 4–100 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the power range of the EQUINOX2 T?
From 4 to 100 kW, and all models are three-phase grid-tied.
What is the SiC technology useful for in the EQUINOX2 T-RV inverter?
Switches on silicon carbide have lower switching losses, so the inverter heats less and needs a smaller heatsink.
Where to see the operating data of the EQUINOX2 T?
On the OLED display of the inverter, and also on the EQUINOX portal and in the app.
Is the EQUINOX2 T suitable for an industrial 100 kW solar plant?
Yes, the largest model of the range has 100 kW. For larger plants several inverters are installed in parallel.
How does the EQUINOX2 T differ from the hybrid EQUINOX2 HT?
The T works only with the grid at 4–100 kW, while the HT connects a battery, has up to 6 modes and switches to backup in less than 10 ms.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.







