Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

Verto — three-phase grid-tied string inverter 15–33.3 kW

The Verto three-phase grid-tied string inverter comes in 15, 17.5, 20 and 25 kW ratings with 3 MPPT and 27, 30 and 33.3 kW with 4 MPPT. It is installed on farms, in small businesses, large homes and apartment buildings.

Power
15 / 17.5 / 20 / 25 kW (3 MPPT); 27 / 30 / 33.3 kW (4 MPPT)
DC inputs
4 (15–25 kW); 8 (27–33.3 kW)
MPPT range
150–870 V
Max. DC voltage
1,000 V

Technical specifications

Power15 / 17.5 / 20 / 25 kW (3 MPPT); 27 / 30 / 33.3 kW (4 MPPT)
DC inputs4 (15–25 kW); 8 (27–33.3 kW)
MPPT range150–870 V
Max. DC voltage1,000 V
Ingress protectionIP66
Protectionbuilt-in replaceable AC/DC SPDs, AFCI
CoolingActive Cool Technology
More from the manufacturer’s documentation
Nominal input voltage600 V
DC input voltage range150–1,000 V
Feed-in start voltage150 V
MPP voltage range at rated power210–870 V (15.0); 245–870 V (17.5); 275–870 V (20.0); 335–870 V (25.0, 3 MPPT); 330–870 V (27.0); 360–870 V (30.0); 400–870 V (33.3)
Max. input current per MPPT28 A (a single string can use the full current)
Max. PV short-circuit current50 A per MPPT; 100 A per inverter (3 MPPT) / 150 A (4 MPPT)
Max. PV generator power22,500 / 26,250 / 30,000 / 37,500 Wp (15.0 / 17.5 / 20.0 / 25.0); 40,500 / 45,000 / 50,000 Wp (27.0 / 30.0 / 33.3)
Rated AC output current (400 V)21.7 / 25.4 / 29.0 / 36.2 A (15.0 / 17.5 / 20.0 / 25.0); 39.1 / 43.5 / 48.3 A (27.0 / 30.0 / 33.3)
Grid connection3~ (N)PE 380/220, 400/230, 440/254 or 480 V
Grid frequency50 / 60 Hz (range 45–65 Hz)
Total harmonic distortion< 3 % or < 1 % depending on model
Power factor (cos φ)0–1 ind. / cap.
Max. efficiency98.53–98.56 % (15.0–25.0, 3 MPPT); 97.98–98.03 % (27.0–33.3)
European efficiency (ηEU)98.19–98.35 % (15.0–25.0, 3 MPPT); 97.76–97.80 % (27.0–33.3)
MPP adaptation efficiency> 99.9 %
Dimensions (H × W × D)730 × 540 × 278 mm (15.0–25.0, 3 MPPT); 865 × 574 × 279 mm (4 MPPT)
Weight35.2 kg (3 MPPT); 41.75 kg (4 MPPT)
Operating temperature−40 to +60 °C
Permissible humidity0–100 %
Noise emission< 56.5 dB(A) (3 MPPT); < 54.6 dB(A) (4 MPPT)
Max. altitude3,000 m (unrestricted) / 4,000 m (restricted voltage range)
Installationindoor and outdoor, 90°–10° tilt; protection class I; overvoltage category DC/AC 2/3
Night-time consumption< 16 W
AC connection4–35 mm², Al and Cu; M32 cable gland (Ø 12–24.5 mm), optional M50 (Ø 10–35 mm)
Surge protection typesDC type 1+2 (IEC 61643-31), AC type 2 (IEC 61643-11) for 15.0–25.0; DC and AC type 1+2 or 2 for 27.0–33.3
Built-in protection devicesDC insulation monitoring, DC disconnector, RCMU, reverse polarity protection
InterfacesWLAN 802.11b/g; 2 × Ethernet LAN RJ45 (10/100 Mbit/s, up to 100 m); 2 × RS485 (Modbus RTU SunSpec / Smart Meter); 6 inputs and 6 digital I/Os; Wired Shutdown; integrated datalogger and web server
StandardsIEC 62109-1/-2, VDE-AR-N 4105:2018, VDE-AR-N 4110:2023-09, EN 50549-1/-2, CEI 0-16, CEI 0-21, UNE 217002:2020, IEC 62116, IEC 61727, AS/NZS 4777.2:2020+A1, IEC 63027:2023, G99
Country of manufactureAustria
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

High-current multi-MPPT handles complex roofs and modules facing different directions, with up to 28 A per tracker and a single string able to use all of it. The 15–25 kW models have 4 DC inputs, and the 27–33.3 kW models have 8. The MPPT range is 150–870 V, feed-in starts at 150 V and maximum DC voltage is 1,000 V. Replaceable AC and DC SPDs are built into the housing next to insulation monitoring, a DC disconnector, an RCMU and reverse polarity protection, and AFCI arc fault protection is included. AC cable of 4–35 mm² aluminum or copper enters through an M32 gland. Ingress protection is IP66, cooling uses Active Cool Technology, and the operating range is −40 to +60 °C. The inverter is made in Austria.

How to choose

Choose the rating by array size. The Verto 25.0 takes up to 37,500 Wp of modules and the Verto 33.3 up to 50,000 Wp, which is one and a half times the AC rating. Note that the larger 4 MPPT models are bigger, 865 × 574 × 279 mm and 41.75 kg against 35.2 kg. If a battery and backup are needed, take the hybrid Verto Plus at 15–33.3 kW, and for 50 kW per unit the Tauro fits.

Request a price and lead time

Verto — three-phase grid-tied string inverter 15–33.3 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many MPPTs does the Verto 33.3 kW have?

4 MPPTs and 8 DC inputs, like all 27–33.3 kW models.

What is the maximum input voltage of the Verto inverter?

1,000 V DC, with an MPPT range of 150–870 V.

Does Verto have built-in surge protection?

Yes, the IP66 housing contains replaceable AC and DC SPDs plus AFCI.

What is the efficiency of the Verto inverter?

Peak efficiency is 98.53–98.56 % on the 15.0–25.0 models and 97.98–98.03 % on the 27.0–33.3 models.

How loud is the Verto in operation?

Below 56.5 dB(A) for the 3 MPPT versions and below 54.6 dB(A) for the 4 MPPT versions, so it is better kept away from bedroom windows.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.