Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

EA BTS 10300 — battery cycling and test system up to 3,84 MW

The BTS 10300 rack system cycles and tests high-voltage battery modules and packs with a voltage of up to 1500 V DC, with a 2000 V option, at a power of 300 kW per 42U rack. Parallel racks scale it up to 3,84 MW. Discharge energy returns to the grid with an efficiency of up to 96,5 %.

Voltage
0–1500 V DC (2000 V option)
Power
300 kW in a 42U rack; up to 3,84 MW with parallel racks
Current
up to 2400 A per rack, up to 30 720 A in total
Energy returned to the grid
efficiency up to 96,5 %

Technical specifications

Voltage0–1500 V DC (2000 V option)
Power300 kW in a 42U rack; up to 3,84 MW with parallel racks
Currentup to 2400 A per rack, up to 30 720 A in total
Energy returned to the gridefficiency up to 96,5 %
Dynamicstransition speed up to 500 µs, data acquisition up to 1,6 kHz
Testsdriving cycles FUDS, SFUDS, GSFUDS, DST, ECE-ISL; insulation resistance
Coolingair or water (option)
SoftwareEA-BTS, 24″ touch panel

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The system controls a climate chamber and exchanges data with the battery BMS via CAN, so the temperature mode and the state of the pack are visible in one interface. Current reaches 2400 A per rack and up to 30 720 A in the full configuration. Transitions between modes take up to 500 µs, and data is recorded at a rate of up to 1,6 kHz. The built-in driving cycles FUDS, SFUDS, GSFUDS, DST and ECE-ISL reproduce real driving profiles of an electric vehicle, and a separate test measures insulation resistance. Everything is controlled by the EA-BTS software with a 24″ touch panel. Cooling is by air or, optionally, by water.

How to choose

The main thing in selection is the pack voltage, the standard 1500 V or the optional 2000 V, and the required power, in multiples of 300 kW per rack. One rack is enough for a single platform, and several racks in parallel give up to 3,84 MW. When a more compact installation for a single pack up to 920 V is needed, BPTS 20920-720 at 180 kW is suitable, for modules BMTS 20200-840-2, and for cells the 18-channel BCTS 20010-600-18.

Request a price and lead time

EA BTS 10300 — battery cycling and test system up to 3,84 MW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What maximum battery voltage does BTS 10300 support?

As standard 0–1500 V DC, with an option up to 2000 V.

What power does one BTS 10300 rack have?

300 kW in a 42U rack, and parallel racks give up to 3,84 MW and up to 30 720 A.

What driving cycles are built into BTS 10300?

FUDS, SFUDS, GSFUDS, DST and ECE-ISL, as well as insulation resistance measurement.

Can BTS 10300 control a climate chamber?

Yes, the system controls a climate chamber and receives data from the BMS via CAN.

What are the transition speed and data recording rate in BTS 10300?

Transition between modes up to 500 µs, data acquisition at a rate of up to 1,6 kHz.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.