Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

EA BIM 20005 — 20-channel battery impedance meter (EIS)

The BIM 20005 impedance meter measures the impedance of lithium-ion cells by electrochemical impedance spectroscopy (EIS) on 20 channels at once. The frequency range is 1 mHz – 10 kHz and impedance is 0,1–100 mΩ with an |Z| accuracy better than 1 %. The device is built into battery test systems.

Channels
20 EIS measuring + 20 PT100 temperature
Frequency range
1 mHz – 10 kHz
AC excitation current
up to 10 A (peak-to-peak)
DC voltage / current
0–5 V / ±1 A (charge and discharge)

Technical specifications

Channels20 EIS measuring + 20 PT100 temperature
Frequency range1 mHz – 10 kHz
AC excitation currentup to 10 A (peak-to-peak)
DC voltage / current0–5 V / ±1 A (charge and discharge)
Impedance range0,1–100 mΩ
|Z| accuracy< 1 %
InterfacesUSB, CAN
Supply / housing100–230 V AC, < 60 W; 19″ 3U

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Excitation is multi-frequency, so the spectrum is recorded faster than with sequential frequency scanning. The AC excitation current reaches 10 A (peak-to-peak), and the DC component of 0–5 V / ±1 A makes it possible to measure a cell under charge or discharge. Twenty PT100 temperature inputs are added to the 20 measuring channels, so the impedance of each cell is tied to its temperature. Data is exchanged with the control system via USB or CAN. The device consumes less than 60 W from a 100–230 V AC grid and takes up 3U in a 19″ rack.

How to choose

The main limitation of BIM 20005 is the 0–5 V voltage, so the device works with individual cells, not with modules. Twenty channels are convenient for incoming inspection of cell batches and sorting them by condition. For cycling the cells themselves with large currents it is complemented by the 18-channel cycler BCTS 20010-600-18, and modules are tested on BMTS 20200-840-2.

Request a price and lead time

EA BIM 20005 — 20-channel battery impedance meter (EIS). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many channels does the BIM 20005 impedance meter have?

20 EIS measuring channels and 20 PT100 temperature channels.

What is the measurement frequency range of BIM 20005?

From 1 mHz to 10 kHz with multi-frequency excitation.

What impedance measurement accuracy does BIM 20005 have?

The |Z| error is less than 1 % in the range of 0,1–100 mΩ.

Can cell impedance be measured under charging current?

Yes, the DC component up to ±1 A at 0–5 V makes it possible to measure under charge and discharge.

How is BIM 20005 connected to a test system?

Via USB or CAN, so the device is connected to a PC or to the bus of the test system. The housing is 3U for a 19″ rack, with a 100–230 V AC supply.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.