EA BMTS 20200-840-2 — battery module test system 2×60 kW
Country: Germany · Model: BMTS 20200-840-2
BMTS 20200-840-2 has two 60 kW channels for charging and discharging battery modules with a voltage of up to 200 V and a current of up to 840 A. The two-channel rack tests two modules at the same time and returns discharge energy to the grid.
- Channels
- 2
- Power
- 60 kW per channel
- Voltage
- 0–200 V per channel
- Current
- 0–840 A per channel
Technical specifications
| Channels | 2 |
|---|---|
| Power | 60 kW per channel |
| Voltage | 0–200 V per channel |
| Current | 0–840 A per channel |
| Regeneration | efficiency up to 95,3 % |
| Version | 42U rack, 3-phase 400 V 50 Hz |
| Command and measurement speed | up to 1 ms |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Each channel delivers 0–200 V and 0–840 A, and the total power of the rack is 2×60 kW. Discharge energy is regenerated to the grid with an efficiency of up to 95,3 %, so long cycles do not require powerful air conditioning of the room. Commands and measurements are updated at intervals of up to 1 ms. The equipment is mounted in a 42U cabinet and powered from a 3-phase 400 V 50 Hz grid. A current of up to 840 A per channel makes it possible to test high-capacity modules with accelerated charging profiles. In practice the rack is used for incoming inspection and endurance tests of modules before they are assembled into a pack.
How to choose
The 200 V limit per channel makes this tester a tool specifically for modules, and for an assembled pack up to 920 V the BPTS 20920-720 at 180 kW is suitable. Individual cells up to 10 V are better run on the 18-channel BCTS 20010-600-18, where each channel has 6 kW. If there are many modules, the two BMTS channels double the laboratory throughput without a second cabinet.
Request a price and lead time
EA BMTS 20200-840-2 — battery module test system 2×60 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How many channels does BMTS 20200-840-2 have?
Two channels, each up to 60 kW, 0–200 V and 0–840 A.
What is the regeneration efficiency of the BMTS module tester?
Up to 95,3 %; discharge energy returns to the three-phase 400 V 50 Hz grid.
Is BMTS suitable for testing a full battery pack?
Only if the pack voltage is up to 200 V. For packs up to 920 V, BPTS 20920-720 is intended.
How fast does BMTS respond to commands?
The command and measurement interval is up to 1 ms, which makes it possible to reproduce dynamic current profiles.
What enclosure is BMTS 20200-840-2 supplied in?
In a 42U rack with a 3-phase 400 V 50 Hz supply; both channels are mounted in one cabinet.