Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

BMV-712 Smart and SmartShunt — battery monitors

The BMV-712 Smart and SmartShunt battery monitors measure current through a shunt, rated 300, 500, 1,000 or 2,000 A on the SmartShunt. The BMV comes with a 500 A/50 mV shunt. They fit any DC system with lead-acid or lithium batteries.

Shunt
300, 500, 1,000, 2,000 A (SmartShunt); 500 A/50 mV (BMV)
Measurements
voltage, current, SoC, time to go, midpoint
Communication
Bluetooth, VE.Direct

Technical specifications

Shunt300, 500, 1,000, 2,000 A (SmartShunt); 500 A/50 mV (BMV)
Measurementsvoltage, current, SoC, time to go, midpoint
CommunicationBluetooth, VE.Direct
Customs codes (for reference)
HS code9030.33
UKTZED code (Ukraine)9030337000
CN code (EU)90303370

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The shunt goes in the negative battery lead, so all charge and load current passes through it. The monitor measures voltage and current and uses them to calculate state of charge (SoC) and remaining runtime. Midpoint monitoring shows imbalance between the two halves of a battery bank and catches a weak block in a series string early. Data goes to a smartphone over Bluetooth and to a system controller over VE.Direct. This shows how much energy is really left instead of just the terminal voltage, which on LiFePO4 barely moves until the bank is almost empty. The BMV-712 Smart has its own display for panel mounting, while the SmartShunt has none and is read from the app or a GX controller.

How to choose

The shunt rating should cover the highest continuous current of the system, inverter draw included. A small system with a panel display takes the BMV-712 Smart with its 500 A/50 mV shunt. For large inverters such as the MultiPlus at 5 kVA or the Quattro, the SmartShunt at 1,000 or 2,000 A matches the current. Where a Cerbo GX is installed, the SmartShunt feeds it over VE.Direct and the data reaches the VRM portal.

Request a price and lead time

BMV-712 Smart and SmartShunt — battery monitors. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What current ratings does the SmartShunt come in?

The SmartShunt is made for 300, 500, 1,000 and 2,000 A.

Which shunt comes with the BMV-712 Smart?

A 500 A/50 mV shunt.

What does the SmartShunt measure?

Voltage, current, SoC, remaining runtime and the bank midpoint.

Where is the SmartShunt connected?

In the negative lead between the battery and all loads and chargers, so every amp passes through the shunt.

Why is midpoint monitoring useful?

It compares the two halves of a series bank and shows imbalance before a weak block pulls the whole string down.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.