basic error ±0.25 % · output 4–20 mA, 0–20 mA, 0–5 mA, 0–10 V · supply 24 V (12–30 V) · IP20

The БПТ-21 is a single-channel signal conditioner for thermocouples with galvanic isolation, designed for DIN-rail mounting. It accepts the low-level signal from a J, L, E, K, S, B or A-1 thermocouple and converts it linearly into a standard analogue current signal of 0–5 mA, 0–20 mA or 4–20 mA, or a 0–10 V voltage signal. The input, output and supply circuits are galvanically separated, which improves noise immunity and the safety of the measuring loop. Cold-junction compensation is provided. The nominal input range is selected from a series between 1 and 100 mV, and the basic conversion error is ±0.25 %. The unit is powered from 24 V (12 to 30 V) and draws no more than 30 mA. Its housing is only 7 mm wide, is rated IP20 and operates at ambient temperatures from -40 to +70 °C. Typical applications include the power industry, metallurgy, and measurement and process automation systems.

Number of independent channels
1
Sensor connection
Two-wire
Thermocouple types
J, L, E, K, S, B, A-1
Temperature measuring range
0–2000 °C

Technical specifications

Number of independent channels1
Sensor connectionTwo-wire
Thermocouple typesJ, L, E, K, S, B, A-1
Temperature measuring range0–2000 °C
Input signal initial value0; 2; 4; 6; 8; 10; 12; 14; 16; 18; 20; 25; 30; 40 mV
Nominal input signal span1; 2; 5; 10; 15; 25; 40; 60; 80; 100 mV
Input scale typeLinear
Basic conversion error± 0.25 %
Output signals0-5 mA, 0-20 mA, 4-20 mA, 0-10 V
Galvanic isolationYes
Supply voltage24 V (12 to 30 V)
Current consumptionmax. 30 mA
MountingDIN rail
Dimensions (HxWxD)94х7х64 mm
Degree of protectionIP20
Weight, max.0.1 kg
Ambient temperature-40 °C to +70 °C
StandardsГОСТ 22261, ГОСТ 26828, ГОСТ 12971, ГОСТ 23170, ГОСТ 15150-69, ДСТУ 2838-94

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

When ordering, specify the thermocouple type (J, L, E, K, S, B, A-1) and the required temperature range within 0–2000 °C. This determines the initial value and span of the input signal in mV. Also specify the output signal: 4–20 mA, 0–20 mA, 0–5 mA or 0–10 V. For two channels, the related models БПТ-658 (76х26х115 mm, 0.2 kg) and БПТ-648 are available. A single-channel alternative is the БПТ-122.

Similar products

Test and measurement

Request a price and lead time

БПТ-21 — thermocouple signal converter with galvanic isolation. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.