CAPDIS-S1+ / CAPDIS-S2+ (R4.5) built-in capacitive voltage indicators (VDIS) for switchgear 1–52 kV

CAPDIS-S1+ and CAPDIS-S2+ (generation R4.5) are built-in systems for verifying the absence of voltage in medium-voltage switchgear of 1–52 kV, per IEC 62271-213:2021 and IEC 61243-5. The device is installed in the front panel of the bay and continuously shows the presence of voltage on three phases through a capacitive divider.

Voltage class
1–52 kV (medium voltage)
Standards
IEC 61243-5, IEC 62271-213
Interface
LRM, three-phase measuring point
Indication
LCD display, three-step voltage level indication; S2+ — coloured LEDs

Technical specifications

Voltage class1–52 kV (medium voltage)
StandardsIEC 61243-5, IEC 62271-213
InterfaceLRM, three-phase measuring point
IndicationLCD display, three-step voltage level indication; S2+ — coloured LEDs
Power supplyS1+ — without battery and auxiliary power; S2+ — relays from 24–230 V AC/DC ± 10 %, < 1 W
Relay outputs (S2+)2 changeover contacts; 250 V AC 5 A / 30 V DC 5 A / 250 V DC 0.3 A; response time ≤ 1 s
Enclosure / cut-out48 × 96 × 37 mm / 45 × 92 mm (DIN IEC 61554)
Degree of protectionIP54
Operating temperature−25 … +55 °C
Frequency50 / 60 Hz
Service life (MTBF)not less than 31 years (S1+), 22 years (S2+)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The device is connected to a capacitive divider formed by a support insulator or a bushing with a capacitive tap. It constantly monitors the response threshold and shows it with a three-step indicator, so periodic repeated tests per IEC 62271-213 and BGV A3 are not required. A full check of the divider insulation is performed from the primary and secondary side. An adjustable 6-step capacitor switching module adjusts the divider and shows the correct setting on the display, which is important for signal processing by CAPDIS-M, IKI-23, IKI-50 and IKI-55 devices. A self-test by button (patent DE 103 04 396) replaces an external tester; detection of conductor breakage and earthing monitoring are available as options. The voltage check and the self-test work without a battery, and the device is intrinsically safe. The built-in Y interface sends signals to IKI indicators and controllers, and the three-phase LRM point is used for phase comparison with the CAP-Phase tester. The 48 × 96 × 37 mm enclosure is installed in a 45 × 92 mm cut-out, with protection degree IP54, temperature −25…+55 °C and frequency 50/60 Hz.

How to choose

The difference between the versions is the relays. S1+ works without auxiliary power and is suitable when only local indication is needed. S2+ has two changeover relays for 250 V AC, 5 A with a 24–230 V AC/DC supply and a response time of not more than 1 s, so it is taken for remote signalling of the presence of voltage. For MTBF, not less than 31 years is stated for S1+ and 22 years for S2+. For ordering, specify the rated voltage Un and the divider capacitance C1. If detection of partial discharges is needed, consider CAPDIS-S1_55 and CAPDIS-S2_55, and for a voltage of 53–480 kV the CAPDIS-S1_HV and CAPDIS-S2_HV series.

Request a price and lead time

CAPDIS-S1+ / CAPDIS-S2+ (R4.5) built-in capacitive voltage indicators (VDIS) for switchgear 1–52 kV. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Is a battery needed for CAPDIS-S1+ to work?

No, the voltage check and the self-test work without a battery and auxiliary power.

How does CAPDIS-S2+ differ from CAPDIS-S1+?

S2+ has two signal relays with changeover contacts of 250 V AC, 5 A, a 24–230 V AC/DC supply and coloured LEDs. The relay response time is not more than 1 s.

What cut-out size is needed for CAPDIS-S1+ and CAPDIS-S2+?

The cut-out is 45 × 92 mm, the enclosure 48 × 96 × 37 mm per DIN IEC 61554. The degree of protection is IP54.

Is periodic testing of the CAPDIS indicator needed?

No, the device constantly monitors the response threshold, so repeated testing per IEC 62271-213 and BGV A3 is not required.

What must be specified when ordering CAPDIS-S1+ or S2+?

The rated voltage Un and the divider capacitance C1. The device works with classes 1–52 kV.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.