Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Clip SGD — maintenance-free single-gas detector for H2S, CO or O2 with a 2-year life

Clip SGD is a disposable single-gas detector for H2S, CO or O2 for hazardous areas that needs no maintenance and runs for two years after activation. Weight is only 93 g for toxic gases. It suits mass equipping of contractor staff, wastewater plants and gas networks.

Gases
H2S, CO or O2
Service life
2 years (> 2900 minutes of alarm); storage before activation up to 6 months
Dimensions / weight
91×54×32 mm; 93 g (toxic), 104 g (O2)
Alarm
LEDs on top, front and side; 90 dB at 10 cm; vibration

Technical specifications

GasesH2S, CO or O2
Service life2 years (> 2900 minutes of alarm); storage before activation up to 6 months
Dimensions / weight91×54×32 mm; 93 g (toxic), 104 g (O2)
AlarmLEDs on top, front and side; 90 dB at 10 cm; vibration
T90< 30 s
Temperature−30…+50 °C
ProtectionIP66 and IP67
Self-testat activation and every 20 h; battery monitoring
Loglast 30 events
Explosion protectionATEX II 1G Ex ia IIC T4 Ga; IECEx; UL-913 / CSA C22.2 No.157 Class I Div 1 and 2
Warranty2 years

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

After two years of operation the device is replaced, not calibrated. There are three versions, for H2S, CO or O2. Dimensions are 91×54×32 mm, weight 93 g for toxic gases and 104 g for oxygen, so it hardly gets in the way during a shift. LEDs are visible from the top, front and side, sound is 90 dB at 10 cm, and there is vibration. The T90 response time is under 30 s, operating temperature from −30 to +50 °C, humidity 15–90 % without condensation, housing IP66 and IP67. A self-test runs at activation and every 20 hours, the battery is monitored continuously, and the log holds the last 30 events. Life is 2 years and more than 2900 minutes in alarm mode, storage before activation up to 6 months. Electromagnetic compatibility per EMC Directive 2014/30/EC, FCC CFR 47 Part 15 and ICES-003. Explosion protection ATEX II 1G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga for zone 0, UL-913 and CSA C22.2 No.157 for Class 1 Div 1 and 2, groups A, B, C and D, T4. Warranty 2 years.

How to choose

The gas is chosen by the hazard at the site, for example hydrogen sulphide at wastewater plants, carbon monoxide in boiler houses and metallurgy, and oxygen to monitor depletion. The disposable format saves sensors and calibration, but the device cannot be refurbished, so for a longer life or several gases take Gasman, Tetra 3 or T4. An unused device is stored for up to 6 months, and the date is on the box label.

Request a price and lead time

Clip SGD — maintenance-free single-gas detector for H2S, CO or O2 with a 2-year life. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How long does Clip SGD work?

Two years after activation and more than 2900 minutes in alarm mode. The warranty is also 2 years.

Which gases does Clip SGD monitor?

There are three versions, for H2S, CO or O2.

Does Clip SGD need calibration?

No, the device is maintenance-free. It tests itself at activation and every 20 hours.

What protection and temperature range does Clip SGD have?

IP66 and IP67, operating temperature −30…+50 °C, T90 response time under 30 s.

How long can Clip SGD be stored before activation?

Up to 6 months, and the date is on the box label.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.