Д5000 — laboratory phase meter for single-phase AC circuits
Country: Ukraine · Model: Д5000
accuracy class 0,2 · −90…0…+90 electrical degrees · 100, 127, 220 V · 5 A, 10 A
The Д5000 is a laboratory phase meter of accuracy class 0,2 for single-phase AC circuits at 50 Hz. It determines the phase shift angle between the fundamental harmonic components of current and voltage, together with the power factor. The phase angle is measured from −90 through 0 to +90 electrical degrees, and the power factor from −1 through 0 to 1. Rated voltage values are 100, 127 and 220 V. Rated current values are 5 A and 10 A. The normal frequency is 50 ± 1 Hz. At rated current and voltage the instrument requires a warm-up time of 1 h. Overall dimensions do not exceed 230 x 280 x 140 mm, and the weight is no more than 7,0 kg. The instrument is intended for precise phase measurements in laboratories. Combined with the И515 current transformer, it can act as a reference standard when calibrating (certifying) Д5780 and Д5781 phase meters, provided the corrections given in its passport are applied.
- Accuracy class
- 0,2
- Phase shift angle measuring range
- −90 – 0 – +90 electrical degrees
- Power factor measuring range
- −1 – 0 – 1
- Rated voltage values
- 100, 127, 220 V
Technical specifications
| Accuracy class | 0,2 |
|---|---|
| Phase shift angle measuring range | −90 – 0 – +90 electrical degrees |
| Power factor measuring range | −1 – 0 – 1 |
| Rated voltage values | 100, 127, 220 V |
| Rated current values | 5 A, 10 A |
| Normal frequency | 50 ± 1 Hz |
| Circuit type | single-phase AC |
| Warm-up time (at rated current and voltage) | 1 h |
| Use as reference standard | calibration of Д5780, Д5781 phase meters (with И515 current transformer) |
| Overall dimensions, max | 230 x 280 x 140 mm |
| Weight, max | 7,0 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Choose the rated voltage (100, 127 or 220 V) and rated current (5 A or 10 A) that match the 50 Hz circuit under test. If the phase meter is to serve as a reference standard for calibrating the Д5780 or Д5781, also provide the И515 current transformer.