Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Д5068, Д5069, Д5070, Д5071 — laboratory three-phase wattvarmeters

accuracy class 0.5/1.0 · 150–3000 W/var · 45–1100 Hz · 1 and 5 A

The Д5068, Д5069, Д5070 and Д5071 wattvarmeters are laboratory instruments that measure active and reactive power in three-phase three-wire AC circuits. Active power can be measured under both balanced and unbalanced phase loads. Reactive power is measured with symmetrical voltage and a phase load imbalance of no more than 5%. In the normal frequency range of 45–65 Hz, the instruments achieve accuracy class 0.5 for both active and reactive power. In the working range above 65 Hz and up to 1100 Hz, class 1.0 applies to active power. Range end values span 150 to 3000 W or var, and the nominal power factor is 1. The case measures approximately 140 × 195 × 92 mm, and the instrument weighs no more than 2.0 kg. Typical uses are laboratories, test benches and calibration areas where three-phase load power is checked. Equivalents: Д50311, Д50312, Д50313, Д50314.

Accuracy class
0.5 (active and reactive power, 45–65 Hz); 1.0 (active power, above 65 to 1100 Hz)
Measured quantities
active and reactive power
Circuit type
three-phase three-wire AC
Nominal current
1 A (Д5068); 5 A (Д5070)

Technical specifications

Accuracy class0.5 (active and reactive power, 45–65 Hz); 1.0 (active power, above 65 to 1100 Hz)
Measured quantitiesactive and reactive power
Circuit typethree-phase three-wire AC
Nominal current1 A (Д5068); 5 A (Д5070)
Nominal voltage100 V; 600 V
Range end values150, 250, 375, 800, 2000, 3000 W or var
Normal frequency range45–65 Hz
Working frequency rangeabove 65 to 1100 Hz
Nominal power factor1
Phase load imbalance for reactive power measurementno more than 5%
Dimensions(140 ± 1.25) × (195 ± 1.45) × (92 ± 2.7) mm
Weightmax. 2.0 kg
EquivalentsД50311, Д50312, Д50313, Д50314

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Choose the model by the circuit's nominal current and the required measuring limit. The Д5068 is rated for 1 A and 100 V, with limits of 150, 250 and 375 W/var. The Д5070 is rated for 5 A and 100 V, with limits of 800 and 2000 W/var. The Д5069 and Д5071 cover higher limits, up to 3000 W/var. Confirm the exact current, voltage and limit combination against the version table.

Similar products

Test and measurement

Request a price and lead time

Д5068, Д5069, Д5070, Д5071 — laboratory three-phase wattvarmeters. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.