Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

YTA70P Temperature Transmitter

The YTA70P is a panel-mount temperature transmitter for DIN rail mounting. It accepts a thermocouple, RTD, ohm or DC millivolt input and converts it into a 4 to 20 mA DC signal. The HART protocol is supported.

Date
Remarks
2024/12
Important Notice for Safe Use of Products

Technical specifications

DateRemarks
2024/12Important Notice for Safe Use of Products

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The transmitter sits on a standard DIN rail inside the cabinet, so the sensor can stay in the field while the signal conditioner is placed next to the controller. One and the same unit handles a thermocouple, an RTD, a resistance in ohms and a millivolt signal, which shortens the spare parts list. The output is a standard 4 to 20 mA DC signal that any PLC or control system accepts. The HART protocol adds a digital channel for configuration and diagnostics without breaking the loop. The specification lists an important notice for safe use of the products dated 2024/12, which should be read before installation.

How to choose

For the YTA70P, first confirm the primary sensor type, thermocouple, RTD, resistance or millivolts, since the input setup depends on it. The 4 to 20 mA DC output suits most controllers, and HART is needed if you want to configure the unit remotely. Accuracy is not given in the data and depends on the sensor type, so check it in the documentation. For field mounting without a cabinet, a different type of transmitter is required.

Request a price and lead time

YTA70P Temperature Transmitter. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which sensors can be connected to the YTA70P?

Thermocouples, RTDs, ohm sources and DC millivolt signals.

What output signal does the YTA70P have?

A standard 4 to 20 mA DC current signal. It can go to a PLC, a controller or a recorder.

How is the YTA70P mounted?

On a standard DIN rail in a cabinet, as it is a panel-mount type.

Does the YTA70P support the HART protocol?

Yes, HART is supported. It makes it possible to configure and diagnose the unit over the same current loop.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.