Э35000 — laboratory phase meter, accuracy class 0.2
Country: Ukraine · Model: Э35000
accuracy class 0.2 · 0–360 electrical degrees · 100, 127, 220 V · 60 Hz
The Э35000 is a laboratory phase meter that measures the phase displacement angle between the fundamental harmonics of current and voltage. It operates at a harmonic factor of no more than 5 %. The instrument covers the full 0–90–180–270–360 electrical-degree circle and also reads power factor over 1–0–1–0–1. Rated voltages are 100, 127 and 220 V, the reference frequency is 60 Hz, and the rated currents are 5 and 10 A. Without a current transformer and without corrections, it meets accuracy class 0.2 at series-circuit currents from 20 to 100 %. Combined with the И515 current transformer and with the corrections from its passport applied, the error referred to full scale does not exceed 0.1 %. In this configuration it serves as a reference instrument for verifying and certifying Д578 and Д5782 phase meters. The instrument is repairable. Dimensions are no more than 230 × 280 × 140 mm, and weight is no more than 7.0 kg.
- Phase angle measuring range
- 0 - 90 - 180 - 270 - 360 electrical degrees
- Power factor measuring range
- 1-0-1-0-1
- Rated voltages
- 100, 127, 220 V
- Reference frequency
- 60 Hz
Technical specifications
| Phase angle measuring range | 0 - 90 - 180 - 270 - 360 electrical degrees |
|---|---|
| Power factor measuring range | 1-0-1-0-1 |
| Rated voltages | 100, 127, 220 V |
| Reference frequency | 60 Hz |
| Rated currents | 5 and 10 A |
| Series-circuit currents | 1; 2; 5 and 10 A |
| Accuracy class (without И515, without corrections) | 0.2 |
| Series-circuit current range for class 0.2 | 20–100 % |
| Error with И515 and corrections, referred to full scale | not more than 0.1 % |
| Rated primary currents of И515 current transformer | 1; 2.5; 5 and 10 A |
| Conditions for 0.1 % error | voltage within ±2 % of rated; current switch at 5 A; frequency 60 ± 0.5 Hz; 1 h warm-up; ±1° from horizontal; 20 ± 5 °C |
| Harmonic factor | not more than 5 % |
| Operating position | horizontal |
| Overall dimensions | max. 230 × 280 × 140 mm |
| Weight | max. 7.0 kg |
| Scope of supply | phase meter, technical description and operating instructions, passport |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
For verifying and certifying Д578 and Д5782 phase meters, use the Э35000 together with the И515 current transformer and apply the corrections from its passport. In this mode the error does not exceed 0.1 %. For routine class 0.2 laboratory measurements, use the instrument without the И515 at series-circuit currents of 20–100 % and voltages of 100, 127 or 220 V.
Similar products
Request a price and lead time
Э35000 — laboratory phase meter, accuracy class 0.2. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.