Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Э35000 — laboratory phase meter, accuracy class 0.2

accuracy class 0.2 · 0–360 electrical degrees · 100, 127, 220 V · 60 Hz

The Э35000 is a laboratory phase meter that measures the phase displacement angle between the fundamental harmonics of current and voltage. It operates at a harmonic factor of no more than 5 %. The instrument covers the full 0–90–180–270–360 electrical-degree circle and also reads power factor over 1–0–1–0–1. Rated voltages are 100, 127 and 220 V, the reference frequency is 60 Hz, and the rated currents are 5 and 10 A. Without a current transformer and without corrections, it meets accuracy class 0.2 at series-circuit currents from 20 to 100 %. Combined with the И515 current transformer and with the corrections from its passport applied, the error referred to full scale does not exceed 0.1 %. In this configuration it serves as a reference instrument for verifying and certifying Д578 and Д5782 phase meters. The instrument is repairable. Dimensions are no more than 230 × 280 × 140 mm, and weight is no more than 7.0 kg.

Phase angle measuring range
0 - 90 - 180 - 270 - 360 electrical degrees
Power factor measuring range
1-0-1-0-1
Rated voltages
100, 127, 220 V
Reference frequency
60 Hz

Technical specifications

Phase angle measuring range0 - 90 - 180 - 270 - 360 electrical degrees
Power factor measuring range1-0-1-0-1
Rated voltages100, 127, 220 V
Reference frequency60 Hz
Rated currents5 and 10 A
Series-circuit currents1; 2; 5 and 10 A
Accuracy class (without И515, without corrections)0.2
Series-circuit current range for class 0.220–100 %
Error with И515 and corrections, referred to full scalenot more than 0.1 %
Rated primary currents of И515 current transformer1; 2.5; 5 and 10 A
Conditions for 0.1 % errorvoltage within ±2 % of rated; current switch at 5 A; frequency 60 ± 0.5 Hz; 1 h warm-up; ±1° from horizontal; 20 ± 5 °C
Harmonic factornot more than 5 %
Operating positionhorizontal
Overall dimensionsmax. 230 × 280 × 140 mm
Weightmax. 7.0 kg
Scope of supplyphase meter, technical description and operating instructions, passport

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

For verifying and certifying Д578 and Д5782 phase meters, use the Э35000 together with the И515 current transformer and apply the corrections from its passport. In this mode the error does not exceed 0.1 %. For routine class 0.2 laboratory measurements, use the instrument without the И515 at series-circuit currents of 20–100 % and voltages of 100, 127 or 220 V.

Similar products

Test and measurement

Request a price and lead time

Э35000 — laboratory phase meter, accuracy class 0.2. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.