Э535, Э536 — laboratory AC/DC milliammeters

accuracy class 0.5 · 5–200 mA · 45–1500 Hz

The Э535 and Э536 are portable laboratory milliammeters for measuring alternating and direct electric current. Both instruments have an accuracy class of 0.5. The Э535 covers low currents, with range end values of 5, 10 and 20 mA. The Э536 is rated for 50, 100 and 200 mA. For alternating current, normal and working frequency bands are specified. Overall, the instruments operate from 45 to 1500 Hz, with the exact limits depending on the model and the selected range. The case measures (140±1,25)х(195±1,45)х(96±2,7) mm, and the instrument weighs 1.2±0.08 kg. Both milliammeters are restorable and repairable products. Typical uses include laboratories, calibration and test benches, and the commissioning and inspection of electrical equipment. The Э535 and Э536 can replace the older Э523, Э513/1, Э524 and Э513/3 instruments.

Instrument type
laboratory AC/DC milliammeter
Accuracy class
0.5
Ranges, Э535
5 mA; 10 mA; 20 mA
Ranges, Э536
50 mA; 100 mA; 200 mA

Technical specifications

Instrument typelaboratory AC/DC milliammeter
Accuracy class0.5
Ranges, Э5355 mA; 10 mA; 20 mA
Ranges, Э53650 mA; 100 mA; 200 mA
Normal frequency band, Э53549–51 Hz (5 mA); 45–65 Hz (10, 20 mA)
Working frequency band, Э535above 65 to 1500 Hz (10, 20 mA)
Normal frequency band, Э53645–100 Hz
Working frequency band, Э536above 100 to 800 Hz (50 mA); above 100 to 1500 Hz (100, 200 mA)
Overall dimensions, mm(140±1,25)х(195±1,45)х(96±2,7)
Weight, kg1.2±0.08
Maintainabilityrestorable, repairable product
Equivalent toЭ523, Э513/1, Э524, Э513/3
Scope of supplyinstrument — 1 pc; technical description and operating manual — 1 copy; data sheet — 1 copy

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The choice depends on the current to be measured. For currents up to 20 mA, choose the Э535 with ranges of 5, 10 and 20 mA. Its working frequency band reaches 1500 Hz on the 10 and 20 mA ranges. For currents up to 200 mA, choose the Э536 with ranges of 50, 100 and 200 mA. Its working band extends to 800 Hz on the 50 mA range and to 1500 Hz on the 100 and 200 mA ranges.

Similar products

Test and measurement

Request a price and lead time

Э535, Э536 — laboratory AC/DC milliammeters. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.