Earth resistance meter Ф4103-М1 (Ф4103М1, Ф 4103-М1, F4103-M1), 0.3 Ω – 15 kΩ
Country: Ukraine · Model: F4103-M1
The Ф4103-М1 earth resistance meter, often searched as Ф4103М1 or F4103-M1, measures resistance of earthing systems, soil resistivity and active resistances. It works with and without interference. Ten ranges cover 0.3 Ω to 15 kΩ.
- Ranges
- 0–0.3 Ω … 0–15 kΩ (10 ranges)
- Measured quantities
- resistance of earthing systems, soil resistivity, active resistances
- Operation with interference
- provided
- Kit
- meter, lead, operating manual
Technical specifications
| Ranges | 0–0.3 Ω … 0–15 kΩ (10 ranges) |
|---|---|
| Measured quantities | resistance of earthing systems, soil resistivity, active resistances |
| Operation with interference | provided |
| Kit | meter, lead, operating manual |
| Other spellings | Ф4103М1, Ф 4103-М1, Ф4103 М1, F4103-M1, F4103M1 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
It suits earthing systems of any size, from a substation grid to a single tower electrode. Ranges run from 0–0.3 Ω to 0–15 kΩ, ten in total. Soil resistivity is needed for surveys and earthing design. The procedure is described in the operating manual. The Ф4103-М1 serves acceptance and periodic checks of earthing in power engineering, communications and lightning protection. Measurements are possible next to live installations. The kit includes a meter, a lead and the operating manual. Designations vary, for example Ф4103-М1 (letter Ф, digits 4103, letter М, digit 1), Ф4103М1, Ф 4103-М1 or F4103-M1. These all refer to the same instrument.
How to choose
The choice depends on the task. Checking the grounding of a facility needs only the main ranges. Soil surveys depend on electrode layout and lead length. When ordering, ask a USK ENERGY manager to confirm the kit, measuring limits, verification and documents.
Request a price and lead time
Earth resistance meter Ф4103-М1 (Ф4103М1, Ф 4103-М1, F4103-M1), 0.3 Ω – 15 kΩ. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Are Ф4103-М1 and F4103-M1 the same instrument?
Yes. Cyrillic Ф4103-М1 is the correct spelling. The Latin F4103-M1, Ф4103М1 and Ф 4103-М1 refer to the same meter.
What are the ranges of the Ф4103-М1?
Ten ranges from 0–0.3 Ω to 0–15 kΩ.
Can it measure soil resistivity?
Yes, along with the resistance of earthing systems and active resistances.
Does the instrument work with interference present?
Yes, measurement is possible both with and without interference.
What is included in the kit?
The meter, a lead and the operating manual.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.