Ф5093 — two-channel frequency divider and presettable counter

0.1 Hz – 1 MHz · division ratio 1–999999 · quartz oscillator ±1×10⁻⁶ · 2 channels (A, B)

The Ф5093 is a two-channel laboratory frequency divider. It divides the repetition frequency of incoming electrical signals by a preset ratio. It also generates reference frequencies, pulses of set duration, time intervals and a specified number of pulses, and can serve as a two-channel presettable counter. The division ratio N is set on switches for each channel, from 1 to 999999 in steps of 1. Inputs A and B accept sinusoidal signals from 10 Hz to 1 MHz and pulse signals of either polarity from 0.1 Hz to 1 MHz. Timing is referenced to a built-in quartz oscillator, whose relative frequency error does not exceed ±1×10⁻⁶ for ten days after adjustment. Channel A count results are output to external recording equipment as a serial 8-4-2-1 binary-coded decimal code. Start, stop and reset can be triggered remotely by external pulses. Typical applications are measurement laboratories, signal frequency analysis and pulse counting systems.

Number of channels
2 (A, B)
Sinusoidal signal frequency, inputs A, B
10 Hz – 1 MHz
Pulse signal frequency (either polarity), inputs A, B
0.1 Hz – 1 MHz
Sinusoidal signal voltage (attenuator 1:1 / 1:10)
1–10 V RMS / 10–30 V RMS

Technical specifications

Number of channels2 (A, B)
Sinusoidal signal frequency, inputs A, B10 Hz – 1 MHz
Pulse signal frequency (either polarity), inputs A, B0.1 Hz – 1 MHz
Sinusoidal signal voltage (attenuator 1:1 / 1:10)1–10 V RMS / 10–30 V RMS
Pulse signal amplitude (attenuator 1:1 / 1:10)1–10 V / 10–30 V
«КИНЕМАТОМЕР» inputsinusoidal, 10 Hz – 100 kHz, 1–3 V RMS
Division ratio N1–999999, step 1
Quartz oscillator frequency error±1×10⁻⁶ (for 10 days after adjustment)
Presettable counting errornone with manual start; not more than +1 pulse with external start
Input pulse duration, channels A, Bnot less than 0.5 µs
START / STOP / RESET control pulsespositive, ≥1 µs, rise time ≤0.1 µs, 3–30 V
Input resistance, inputs A, B / control inputsnot less than 47 kΩ / 4.7 kΩ
Input capacitance, inputs A, B / control inputsnot more than 50 pF / 100 pF
Count output (channel A)serial 8-4-2-1 binary-coded decimal
Warm-up timenot more than 1 h
Supply frequency(50±1) Hz
Power consumptionnot more than 60 V·A
Overall dimensions490×380×130 mm
Weightnot more than 11 kg

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Select the input mode according to signal level. Use the 1:1 attenuator for signals of 1–10 V (RMS for sine, peak for pulses). Use the 1:10 attenuator for signals of 10–30 V. A separate «КИНЕМАТОМЕР» input is provided for sinusoidal signals of 1–3 V RMS at 10 Hz – 100 kHz.

Similar products

Test and measurement

Request a price and lead time

Ф5093 — two-channel frequency divider and presettable counter. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.