Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Ф5290 — digital readout device for linear and angular displacement

−9999999 to +9999999 (linear displacement) · error 0.001 of a synchro rotor revolution · up to 1200 rpm synchro rotor speed · supply 85–242 V, 49–61 Hz

The Ф5290 is a digital readout device that monitors linear or angular displacement along a single coordinate axis. It uses a БС-155А synchro as the primary transducer and converts the synchro signal into a numerical position reading for a moving machine-tool or machine assembly. Linear displacement is shown from −9999999 to +9999999. Angular displacement is shown from 0.00.00 to 359.59.59 in degrees, minutes and seconds, or from 0 to 359.999 in decimal degrees. The limit of systematic error, including the synchro, is 0.001 of a rotor revolution. The scaling conversion coefficient can be selected from 100 to 30000 pulses per revolution. The device offers backlash compensation, reference-point functions and positioning commands. An RS232C interface is available on separate order. It runs from an 85–242 V supply, draws no more than 8 W and has an IP43 enclosure. It is used in digital readout systems for metalworking machine tools and in information-measuring systems.

Linear displacement display range
−9999999 to +9999999
Angular displacement range (deg, min, sec)
0.00.00 – 359.59.59
Angular displacement range (decimal degrees)
0 – 359.999
Absolute angular displacement within one rotor revolution
0.0 – 359.59

Technical specifications

Linear displacement display range−9999999 to +9999999
Angular displacement range (deg, min, sec)0.00.00 – 359.59.59
Angular displacement range (decimal degrees)0 – 359.999
Absolute angular displacement within one rotor revolution0.0 – 359.59
Limit of systematic error (with synchro)0.001 of a synchro rotor revolution
Scaling conversion coefficient100 – 30000 pulses/rev
Scaling factor0.000001 – 9.999999
Count increment1 – 99 least-significant-digit units
Synchro rotor speed0 – 1200 rpm
Primary transducersynchro БС-155А
InterfaceRS232C (on separate order)
Supply voltage85 – 242 V AC
Supply frequency49 – 61 Hz
Power consumptionmax. 8 W
Permissible supply interruptionup to 10 ms (interval at least 1 s)
DC external circuit switching1 – 1000 mA at 5 – 30 V
Control input currentmax. 10 mA at (12 ± 2) V
Warm-up timemax. 5 min
Continuous operationat least 16 h, followed by a break of at least 1 h
Mean recovery timemax. 4 h
Mean service lifeat least 14 years
Ingress protectionIP43
Mechanical groupМ8
Climatic versionУХЛ category 4
Dimensions325 x 315 x 95 mm
Weightmax. 3.5 kg
StandardsГОСТ 27537, ГОСТ 17516.1, ГОСТ 14254, ГОСТ 15150, ГОСТ 13109

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Choose the display mode to suit the task: linear count, angular in degrees, minutes and seconds, or angular in decimal degrees. Select the scaling conversion coefficient (100 to 30000 pulses per revolution) to match the drive kinematics. If data must be passed to external systems, order the version with the RS232C interface, which is supplied on separate order.

Similar products

Test and measurement

Request a price and lead time

Ф5290 — digital readout device for linear and angular displacement. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.