Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Ф5303 — AC millivoltmeter for RMS voltage measurement

1 mV – 300 V (12 ranges) · error ±0.5 % (±1.0 % on 1 and 3 mV) · normal frequency range 50 Hz – 100 kHz · supply (220 ± 22) V, (50 ± 1) Hz

The Ф5303 is a laboratory millivoltmeter for determining the root-mean-square (RMS) value of voltage in AC circuits. It handles both sinusoidal and distorted waveforms, making it suitable for circuits containing harmonics or non-sinusoidal voltages. The instrument offers 12 ranges with full-scale values from 1 mV to 300 V, so a single unit covers everything from weak signals to mains-level voltages. Within the normal frequency range the basic error does not exceed ±0.5 % of full scale on the 10 mV to 300 V ranges and ±1.0 % on the 1 mV and 3 mV ranges. The normal frequency range is 50 Hz to 100 kHz, while the working range extends to 10–50 Hz and 100 kHz – 10 MHz. The meter is powered from (220 ± 22) V, (50 ± 1) Hz AC mains. Typical uses include measurement laboratories, calibration work, commissioning and analysis of AC circuits.

Measured quantity
RMS value of AC voltage
Signal waveform
sinusoidal and distorted
Full-scale values, mV
1; 3; 10; 30; 100; 300 mV
Full-scale values, V
1; 3; 10; 30; 100; 300 V

Technical specifications

Measured quantityRMS value of AC voltage
Signal waveformsinusoidal and distorted
Full-scale values, mV1; 3; 10; 30; 100; 300 mV
Full-scale values, V1; 3; 10; 30; 100; 300 V
Basic error (10 mV – 300 V ranges)not more than ±0.5 % of full scale
Basic error (1 mV and 3 mV ranges)not more than ±1.0 % of full scale
Normal frequency range50 Hz – 100 kHz
Working frequency range10–50 Hz and 100 kHz – 10 MHz
Supply voltage(220 ± 22) V AC
Supply frequency(50 ± 1) Hz

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Select the range whose full-scale value is the next one above the expected voltage, as the error is stated relative to full scale. For the best accuracy (±0.5 %) use the ranges from 10 mV upwards; the 1 mV and 3 mV ranges are rated at ±1.0 %. Rated accuracy applies within 50 Hz – 100 kHz; at 10–50 Hz and 100 kHz – 10 MHz the instrument operates in its working frequency range.

Similar products

Test and measurement

Request a price and lead time

Ф5303 — AC millivoltmeter for RMS voltage measurement. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.