FAUN — calculator (heat calculator) for compact heat and cold meters for metering stations, Qp 0.6–3 000 m³/h

FAUN is a calculator for compact heat and cold meters that works with flow meters of nominal flow from 0.6 to 3 000 m³/h. Depending on the setting, it meters heat, cold, or both in one circuit. It is installed in heating substations, heating network metering stations, and residential, public and industrial buildings.

Purpose
heat calculator of a compact heat meter: metering of heat, cold or heat/cold in one circuit
Nominal flow of connected flow meters
0.6 … 3 000 m³/h
Temperature range
Θmin 1 °C … Θmax 180 °C
Temperature difference
ΔΘmin 3 K … ΔΘmax 175 K

Technical specifications

Purposeheat calculator of a compact heat meter: metering of heat, cold or heat/cold in one circuit
Nominal flow of connected flow meters0.6 … 3 000 m³/h
Temperature rangeΘmin 1 °C … Θmax 180 °C
Temperature differenceΔΘmin 3 K … ΔΘmax 175 K
Error (MPE)Ec = ±(0.5 + ΔΘmin/ΔΘ) %
Temperature sensorsPt500 or Pt100, 2- or 4-wire
Flow metersultrasonic or mechanical (vane wheel/turbine), including those of other manufacturers
Energy unitsGJ, MWh, kWh, Gcal
Archivemore than 5 000 registers; 2 tariff registers; 4 pulse inputs
Supply3.6 V lithium battery (AA, 2×AA, C, D; 6–12 years) or 230 V AC / 24 V AC/DC mains
Environment class / protectionEN 1434 class C, MID E1/M1; 5–55 °C; IP54, IP65 or IP68
Communication2 replaceable modules: M-Bus, RS232, RS485, pulse and analog (4–20 mA / 1–10 V) outputs, LonWorks, Wireless M-Bus, IMR radio; M-Bus, Modbus, Lumbus, LonWorks protocols

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The calculator works with ultrasonic and mechanical flow transducers and with matched Pt500 or Pt100 temperature sensors in a 2- or 4-wire connection, including those of other manufacturers. The temperature range is 1–180 °C, the temperature difference 3–175 K, the error limit Ec = ±(0.5 + ΔΘmin/ΔΘ) %. Energy is shown in GJ, MWh, kWh or Gcal, and volume in m³ on a large eight-digit display. The archive holds more than 5 000 registers, with two independent tariff registers, leak monitoring with two flow meters, and four pulse inputs for water, electricity or gas meters. Supply is from a 3.6 V lithium battery (AA, 2×AA, C or D, 6–12 years) or from 230 V AC or 24 V AC/DC mains. Two communication modules are installed without breaking the verification seals, including M-Bus, RS232, RS485, pulse outputs, analog outputs 4–20 mA or 1–10 V, LonWorks, Wireless M-Bus and IMR. The environment class is EN 1434 C, MID E1/M1, ambient temperature 5–55 °C, protection rating IP54, IP65 or IP68.

How to choose

The mode is set in the configuration: heat only, cold only, or both in one circuit. Switching to cold occurs when the supply temperature is lower than the return temperature and the set threshold. Communication modules are selected for the data collection system, and the M-Bus, Modbus, Lumbus and LonWorks protocols are supported. For mains supply take 230 V AC or 24 V AC/DC, and where there is no mains, the battery.

Request a price and lead time

FAUN — calculator (heat calculator) for compact heat and cold meters for metering stations, Qp 0.6–3 000 m³/h. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which flow meters does the FAUN calculator work with?

With ultrasonic and mechanical transducers of nominal flow from 0.6 to 3 000 m³/h, including those of other manufacturers.

Which temperature sensors connect to FAUN?

Matched Pt500 or Pt100 in a 2- or 4-wire connection.

Can FAUN meter cold?

Yes, it works as a heat meter, a cold meter or a combined one in one circuit. Switching to cold happens when the supply temperature is lower than the return temperature and the threshold.

How long does the FAUN battery last?

The 3.6 V lithium battery (AA, 2×AA, C or D) is rated for 6–12 years of operation. Supply of 230 V AC and 24 V AC/DC is also available.

Which interfaces can be installed in FAUN?

Two independent modules without breaking the verification seals, including M-Bus, RS232, RS485, pulse and analog outputs, LonWorks and Wireless M-Bus.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.