Xgard Bright and Xsafe Bright — Addressable Fixed Gas Detectors with OLED Display and MPS Sensor
Country: United Kingdom · Model: Xgard Bright / Xsafe Bright
An addressable fixed gas detector for flammable and toxic gases and oxygen with a large OLED display. Supply 12–30 V DC, not more than 3 W, outputs 4–20 mA, RS-485 Modbus RTU and three relays. Explosion protection Ex db IIC T6 Gb for zones 1 and 2, while Xsafe Bright is intended for safe areas.
- Sensors
- MPS (10+ years, TrueLEL, no poisoning, no calibration), LLO2 (5 years), IR (10+ years), electrochemical toxic
- Outputs
- 3-wire 4–20 mA (sink/source), RS-485 Modbus RTU, HART 7 (option)
- Relays
- Alarm 1, Alarm 2, Fault (SPDT, 1 A 24 V DC)
- Supply
- 12–30 V DC, not more than 3 W
Technical specifications
| Sensors | MPS (10+ years, TrueLEL, no poisoning, no calibration), LLO2 (5 years), IR (10+ years), electrochemical toxic |
|---|---|
| Outputs | 3-wire 4–20 mA (sink/source), RS-485 Modbus RTU, HART 7 (option) |
| Relays | Alarm 1, Alarm 2, Fault (SPDT, 1 A 24 V DC) |
| Supply | 12–30 V DC, not more than 3 W |
| Housing | aluminium alloy ADC 12 or stainless steel 316; 1–3.5 kg |
| Temperature | ATEX/IECEx −40…+70 °C; UL −40…+60 °C |
| Protection | IP65/66 (EN 60529) |
| Explosion protection | ATEX/IECEx Ex II 2 G Ex db IIC T6 Gb; Ex II 2 D Ex tb IIIC T80 °C Db; zones 1, 2, 21, 22 |
| Repeatability / drift | ±2 % FS; ±2 % FS per year |
| Xsafe Bright | version for safe areas |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The MPS sensor with the TrueLEL function measures many flammable gases with one element, does not get poisoned, needs no calibration and works with hydrogen. Its service life exceeds 10 years, as for the infrared sensors, and the LLO2 oxygen sensor works for 5 years. A four-wire addressable scheme shortens cable runs. Installation, calibration and maintenance are done through the display without opening the housing. The SPDT relays Alarm 1, Alarm 2 and Fault switch 1 A at 24 V DC, there is a siren output, and HART 7 is optional. The housing of ADC 12 alloy or 316 steel weighs from 1 to 3.5 kg, has two entries M20 or 1/2 inch NPT, and IP65/66 protection. The operating temperature is from −40 to +70 °C per ATEX/IECEx and up to +60 °C per UL, humidity 0–95 % non-condensing. Repeatability is ±2 % of full scale, and zero drift is not more than ±2 % of full scale per year. Explosion protection Ex II 2 D Ex tb IIIC T80 °C Db for zones 21 and 22.
How to choose
The task determines the sensor type. For many flammable gases and hydrogen MPS is used, for oxygen LLO2, for hydrocarbons the infrared sensor, and for toxic gases the electrochemical one. The aluminium alloy housing is lighter, while 316 steel is more resistant in an aggressive environment. In a hazardous zone Xgard Bright is needed, and in a safe area Xsafe Bright is enough. For pure hydrocarbons in zones 1 and 2 there are also IRmax and IR Plus.
Request a price and lead time
Xgard Bright and Xsafe Bright — Addressable Fixed Gas Detectors with OLED Display and MPS Sensor. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the service life of Xgard Bright sensors?
MPS and infrared sensors over 10 years, the LLO2 oxygen sensor 5 years.
How does Xgard Bright differ from Xsafe Bright?
Xgard Bright has ATEX and IECEx explosion protection for zones 1, 2, 21 and 22, while Xsafe Bright is made for safe areas.
Does MPS measure hydrogen?
Yes, MPS is ready to work with hydrogen, does not get poisoned and needs no calibration.
What outputs and supply does the detector have?
4–20 mA, RS-485 Modbus RTU, three relays and a siren output, HART 7 optional. Supply 12–30 V DC, not more than 3 W.
What are the temperature and protection ratings?
From −40 to +70 °C per ATEX/IECEx, up to +60 °C per UL, IP65/66.