Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

И508М — measuring current transformer block, accuracy class 0.2

accuracy class 0.2 · 100, 250, 500, 600 A / 5 A · up to 660 V · 45–500 Hz

The И508М is a block of measuring current transformers of accuracy class 0.2. It extends the current and power measurement limits of the К50 measuring set. The block is used in single-phase and three-phase AC circuits rated up to 660 V. It converts a primary current of 100, 250, 500 or 600 A into a rated secondary current of 5 A over a frequency range of 45–500 Hz. The rated burden of each transformer is 0.2 Ohm at cosφ = 0.8–1. Insulation resistance of the secondary windings to the case is not less than 100 MOhm. The insulation withstands test voltages of 2 kV for the secondary windings and 3 kV for the primary windings. At 100–120 % of rated current, the ratio error stays within ±0.2 % and the phase displacement within ±10 min. The unit is designed for enclosed rooms at +10 to +30 °C and relative humidity up to 80 %. It suits laboratories and test benches that need precise measurement of large AC currents and power.

Accuracy class
0.2
Rated primary currents
100, 250, 500, 600 A
Rated primary voltage
660 V
Rated frequency range
45–500 Hz

Technical specifications

Accuracy class0.2
Rated primary currents100, 250, 500, 600 A
Rated primary voltage660 V
Rated frequency range45–500 Hz
Rated secondary current5 A
Rated burden of each transformer (cosφ = 0.8–1)0.2 Ohm
Burden limits23–100 % of rated
Error at 10 % of rated current±0.5 %; ±20 min
Error at 20 % of rated current±0.35 %; ±15 min
Error at 100–120 % of rated current±0.2 %; ±10 min
Insulation resistance of secondary windings to casenot less than 100 MOhm
Test voltage, secondary windings to case2 kV
Test voltage, primary windings to case3 kV
Probability of failure-free operation over 500 h (P* = 0.8)not less than 0.96
Circuitssingle-phase and three-phase AC
CompatibilityК50 measuring set
Operating conditionsenclosed rooms, +10 to +30 °C, humidity up to 80 %
Overall dimensions320х115х250
Weightnot more than 7.5 kg
Scope of supplyИ508М block — 1 pc, connecting leads — 10 pcs, data sheet — 1 copy

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The block offers four rated primary currents: 100, 250, 500 and 600 A. Select the range closest to the current being measured. The lowest error (±0.2 %, ±10 min) is achieved at 100–120 % of rated current. It rises to ±0.35 % at 20 % and to ±0.5 % at 10 %. The secondary burden should be kept within 23–100 % of the rated value.

Similar products

Test and measurement

Request a price and lead time

И508М — measuring current transformer block, accuracy class 0.2. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.