accuracy class 0.1; 0.2 · primary current 0.5–2000 A · secondary current 5 A · 50–1000 Hz

A series of laboratory measuring current transformers for use in AC circuits. Each unit converts the primary current to a standard 5 A secondary current, to which ammeters, wattmeters and other measuring instruments are connected. The range comprises the И54М and И515М for primary currents from 0.5 to 50 A, plus the УТТ-5М and УТТ-6М1/УТТ-6М2 window-type models with a central aperture for currents up to 600 A and up to 2000 A respectively. The И515М is accuracy class 0.1; the other models are class 0.2. The И54М covers a frequency range of 50–1000 Hz, while the other models are rated for 50 Hz. All units retain their characteristics at 60 Hz. Rated secondary burden is 5 or 10 V·A. The rated voltage of the primary winding relative to the case and secondary winding is 660 V. Continuous operation is limited to 8 h, followed by a pause of at least 30 min. Typical applications are laboratory electrical measurements and the verification of measuring instruments.

Accuracy class, И54М
0.2
Accuracy class, И515М
0.1
Accuracy class, УТТ-5М, УТТ-6М1, УТТ-6М2
0.2
Frequency, И54М
50–1000 Hz

Technical specifications

Accuracy class, И54М0.2
Accuracy class, И515М0.1
Accuracy class, УТТ-5М, УТТ-6М1, УТТ-6М20.2
Frequency, И54М50–1000 Hz
Frequency, И515М, УТТ-5М, УТТ-6М1, УТТ-6М250 Hz
Characteristics retainedat 60 Hz
Rated primary current, И54М0.5; 1; 2; 5; 10; 20; 50 A
Rated primary current, И515М0.5; 1; 2.5; 5; 10; 25; 50 A
Rated primary current, УТТ-5М15; 50; 100; 150; 200; 300; 600 A
Rated primary current, УТТ-6М1, УТТ-6М2100; 150; 200; 250; 300; 400; 500; 600; 750; 800; 1000; 1200; 1500; 2000 A
Rated secondary current5 A
Rated secondary burden, И54М10 V·A (cosφ 0.5 to 1)
Rated secondary burden, И515М10 V·A (cosφ 0.8 to 1)
Rated secondary burden, УТТ-5М5 V·A (cosφ 0.8 to 1)
Rated secondary burden, УТТ-6М1, УТТ-6М210 V·A (cosφ 0.8 to 1)
Current error limit (class 0.2)±[0.2+0.04(In/I-1)] %
Phase displacement limit (class 0.2)±[10+1(In/I-1)]'
Current error limit (class 0.1)±[0.1+0.02(In/I-1)] %
Phase displacement limit (class 0.1)±[5+0.5(In/I-1)]'
Primary winding voltage to case and secondary winding660 V
Continuous operation timemax. 8 h
Interval before reconnectionmin. 30 min
Class 0.1 versionsИ515М — plug-type switching device; И515М/1 — terminal-type switching device
Overall dimensions, И54М, И515М185x125x235 mm
Overall dimensions, УТТ-5М164x131x60 mm
Overall dimensions, УТТ-6М1236x190x78 mm
Overall dimensions, УТТ-6М290x195x240 mm
Central aperture diameter, УТТ-5Мmin. 37 mm
Central aperture diameter, УТТ-6М1, УТТ-6М2min. 80 mm
Weight, И54М, И515Мmax. 4 kg
Weight, УТТ-5Мmax. 1.5 kg
Weight, УТТ-6М1, УТТ-6М2max. 3.8 kg

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

For low currents (0.5–50 A), choose the И54М (class 0.2, up to 1000 Hz) or the И515М (class 0.1, 50 Hz). The И515М has a plug-type switching device, while the И515М/1 has a terminal-type one. The УТТ-5М covers 15–600 A (37 mm aperture). The УТТ-6М1 and УТТ-6М2 cover 100–2000 A (80 mm aperture) and differ in overall dimensions.

Similar products

Test and measurement

Request a price and lead time

И54М, И515М, УТТ-5М, УТТ6М1, УТТ6М2 — laboratory measuring current transformers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.