И54М, И515М, УТТ-5М, УТТ6М1, УТТ6М2 — laboratory measuring current transformers
Country: Ukraine · Model: И54М, И515М, УТТ-5М, УТТ6М1, УТТ6М2
accuracy class 0.1; 0.2 · primary current 0.5–2000 A · secondary current 5 A · 50–1000 Hz
A series of laboratory measuring current transformers for use in AC circuits. Each unit converts the primary current to a standard 5 A secondary current, to which ammeters, wattmeters and other measuring instruments are connected. The range comprises the И54М and И515М for primary currents from 0.5 to 50 A, plus the УТТ-5М and УТТ-6М1/УТТ-6М2 window-type models with a central aperture for currents up to 600 A and up to 2000 A respectively. The И515М is accuracy class 0.1; the other models are class 0.2. The И54М covers a frequency range of 50–1000 Hz, while the other models are rated for 50 Hz. All units retain their characteristics at 60 Hz. Rated secondary burden is 5 or 10 V·A. The rated voltage of the primary winding relative to the case and secondary winding is 660 V. Continuous operation is limited to 8 h, followed by a pause of at least 30 min. Typical applications are laboratory electrical measurements and the verification of measuring instruments.
- Accuracy class, И54М
- 0.2
- Accuracy class, И515М
- 0.1
- Accuracy class, УТТ-5М, УТТ-6М1, УТТ-6М2
- 0.2
- Frequency, И54М
- 50–1000 Hz
Technical specifications
| Accuracy class, И54М | 0.2 |
|---|---|
| Accuracy class, И515М | 0.1 |
| Accuracy class, УТТ-5М, УТТ-6М1, УТТ-6М2 | 0.2 |
| Frequency, И54М | 50–1000 Hz |
| Frequency, И515М, УТТ-5М, УТТ-6М1, УТТ-6М2 | 50 Hz |
| Characteristics retained | at 60 Hz |
| Rated primary current, И54М | 0.5; 1; 2; 5; 10; 20; 50 A |
| Rated primary current, И515М | 0.5; 1; 2.5; 5; 10; 25; 50 A |
| Rated primary current, УТТ-5М | 15; 50; 100; 150; 200; 300; 600 A |
| Rated primary current, УТТ-6М1, УТТ-6М2 | 100; 150; 200; 250; 300; 400; 500; 600; 750; 800; 1000; 1200; 1500; 2000 A |
| Rated secondary current | 5 A |
| Rated secondary burden, И54М | 10 V·A (cosφ 0.5 to 1) |
| Rated secondary burden, И515М | 10 V·A (cosφ 0.8 to 1) |
| Rated secondary burden, УТТ-5М | 5 V·A (cosφ 0.8 to 1) |
| Rated secondary burden, УТТ-6М1, УТТ-6М2 | 10 V·A (cosφ 0.8 to 1) |
| Current error limit (class 0.2) | ±[0.2+0.04(In/I-1)] % |
| Phase displacement limit (class 0.2) | ±[10+1(In/I-1)]' |
| Current error limit (class 0.1) | ±[0.1+0.02(In/I-1)] % |
| Phase displacement limit (class 0.1) | ±[5+0.5(In/I-1)]' |
| Primary winding voltage to case and secondary winding | 660 V |
| Continuous operation time | max. 8 h |
| Interval before reconnection | min. 30 min |
| Class 0.1 versions | И515М — plug-type switching device; И515М/1 — terminal-type switching device |
| Overall dimensions, И54М, И515М | 185x125x235 mm |
| Overall dimensions, УТТ-5М | 164x131x60 mm |
| Overall dimensions, УТТ-6М1 | 236x190x78 mm |
| Overall dimensions, УТТ-6М2 | 90x195x240 mm |
| Central aperture diameter, УТТ-5М | min. 37 mm |
| Central aperture diameter, УТТ-6М1, УТТ-6М2 | min. 80 mm |
| Weight, И54М, И515М | max. 4 kg |
| Weight, УТТ-5М | max. 1.5 kg |
| Weight, УТТ-6М1, УТТ-6М2 | max. 3.8 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
For low currents (0.5–50 A), choose the И54М (class 0.2, up to 1000 Hz) or the И515М (class 0.1, 50 Hz). The И515М has a plug-type switching device, while the И515М/1 has a terminal-type one. The УТТ-5М covers 15–600 A (37 mm aperture). The УТТ-6М1 and УТТ-6М2 cover 100–2000 A (80 mm aperture) and differ in overall dimensions.
Similar products
Request a price and lead time
И54М, И515М, УТТ-5М, УТТ6М1, УТТ6М2 — laboratory measuring current transformers. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.