И561 — laboratory current transformer, accuracy class 0.02
Country: Ukraine · Model: И561
accuracy class 0.02 · 0.5–100 A / 5 A · 45–65 Hz · 660 V
The И561 is a laboratory current transformer for single-phase AC circuits at 50 Hz. It converts a primary current of 0.5 to 100 A into a standardised secondary current of 5 A. This allows standard measuring instruments to be connected and high-precision comparisons to be made. Permissible error limits correspond to accuracy class 0.02. The unit therefore serves as a reference standard for verifying current transformers and for precise electrical measurements in laboratories and metrology departments. The primary winding offers 13 rated current values, and the measuring range is 2–120% of the rated value. The rated voltage of the primary winding relative to the case and secondary winding is 660 V. The rated secondary load is 5 VA at a power factor of 1, and the normal frequency range is 45–65 Hz. Continuous operation at rated current is limited to 8 h. Overall dimensions do not exceed 400 x 300 x 130 mm, and the weight is no more than 25 kg.
- Type
- laboratory current transformer, single-phase
- Accuracy class
- 0.02
- Rated primary currents
- 0.5; 1; 2.5; 5; 10; 15; 20; 30; 40; 50; 60; 80; 100 A
- Primary current measuring range
- 2–120% of rated value
Technical specifications
| Type | laboratory current transformer, single-phase |
|---|---|
| Accuracy class | 0.02 |
| Rated primary currents | 0.5; 1; 2.5; 5; 10; 15; 20; 30; 40; 50; 60; 80; 100 A |
| Primary current measuring range | 2–120% of rated value |
| Rated secondary current | 5 A |
| Rated voltage of primary winding to case and secondary winding | 660 V |
| Rated secondary load | 5 VA at power factor 1 |
| Normal frequency range | 45–65 Hz |
| Power consumption at rated primary current 0.5 / 100 A | max. 15 / 40 VA |
| Continuous operation at rated current | max. 8 h |
| Ratio of operating time to rest interval | max. 4 |
| Overall dimensions | max. 400 x 300 x 130 mm |
| Weight | max. 25 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the rated primary current from the series 0.5, 1, 2.5, 5, 10, 15, 20, 30, 40, 50, 60, 80 and 100 A. Base the choice on the expected current of the transformer under test or of the measuring circuit. That current should fall within 2–120% of the chosen rating. The secondary current remains 5 A for every rating.