Infrared Gas Analyzer IR800G, IR810G

The IR800G and IR810G infrared gas analyzers measure up to 5 components at the same time, with ranges from 0–50 ppm up to 100 vol%. They go into continuous emission monitoring systems (CEMS) and combustion control loops.

Component
Range
NO
0-50 ppm to 0-5000 ppm (Optional range : 0-50 ppm to 0-199 ppm)
SO2
0-50 ppm to 0-5000 ppm, 0-2 vol% to 0-10 vol% (Optional range : 0-50 ppm to 0-199 ppm)
CO
0-50 ppm to 0-5000 ppm, 0-2 vol% to 0-100 vol% (Optional range : 0-50 ppm to 0-199 ppm, 0-51 vol% to 0-100 vol%)

Technical specifications

ComponentRange
NO0-50 ppm to 0-5000 ppm (Optional range : 0-50 ppm to 0-199 ppm)
SO20-50 ppm to 0-5000 ppm, 0-2 vol% to 0-10 vol% (Optional range : 0-50 ppm to 0-199 ppm)
CO0-50 ppm to 0-5000 ppm, 0-2 vol% to 0-100 vol% (Optional range : 0-50 ppm to 0-199 ppm, 0-51 vol% to 0-100 vol%)
CO20-1000 ppm to 100 vol% (Optional range : 0-1000 ppm to 0-4999 ppm, 0-26 vol% to 0-100 vol%)
CH40-2 vol% to 0-100 vol% (Optional range : 0-51 vol% to 0-100 vol%)
O20-5 vol% to 0-100 vol% * 0-25 vol% to 0-100 vol% for hydrogen background

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The infrared method gives minimal drift and stable readings, so control loops can run on them without frequent re-tuning. One analyzer covers NO, SO2, CO, CO2, CH4 and O2, so there is no need for a separate instrument per gas. The standard NO range runs from 0–50 ppm to 0–5000 ppm. SO2 and CO share the same ppm limits and add volume percent, up to 0–10 vol% for SO2 and up to 0–100 vol% for CO. CO2 is measured from 0–1000 ppm to 100 vol%. CH4 spans 0–2 to 0–100 vol%, O2 spans 0–5 to 0–100 vol%, and on a hydrogen background oxygen starts at 0–25 vol%.

How to choose

Start from the list of components and the limits you need. Emission control calls for narrow ppm ranges, while process gases with a percent-level CO or CH4 content fit scales up to 100 vol%. Optional ranges shift the standard ones, for example 0–50 to 0–199 ppm for NO and SO2, or up to 0–4999 ppm for CO2. If only oxygen in a flammable mixture is needed, look at the paramagnetic oxygen analyzers in the catalog.

Request a price and lead time

Infrared Gas Analyzer IR800G, IR810G. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many gases can the IR800G measure at once?

Up to 5 components at the same time, chosen from NO, SO2, CO, CO2, CH4 and O2.

Which CO ranges are available on the IR810G?

Standard ranges run from 0–50 ppm to 0–5000 ppm and from 0–2 to 0–100 vol%. Optional ranges are 0–50 to 0–199 ppm and 0–51 to 0–100 vol%.

Is the analyzer suitable for CEMS?

Yes, it is built for continuous emission monitoring and combustion control. Minimal drift keeps the measurement stable.

Can oxygen be measured on a hydrogen background?

Yes. On a hydrogen background the O2 range starts at 0–25 vol% and reaches 0–100 vol%, without hydrogen the scale starts at 0–5 vol%.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.