Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

ІПМ-101 — single-phase network parameter indicator

AC 2.6...260 V (direct connection) · 0.05...5.0 A (direct connection) · U and I error ±0.25 % · 45...65 Hz

The ІПМ-101 is a panel indicator for monitoring the electrical parameters of a single-phase network. Measured signals are applied to two separate inputs, one for voltage and one for current. From these, the unit determines voltage, current, fundamental frequency and power factor. It also calculates active, reactive and apparent power as instantaneous, average and accumulated values. With direct connection, it covers AC 2.6...260 V and 0.05...5.0 A, and external transformers extend these ranges considerably. The basic reduced error is ±0.25 % for voltage and current, ±0.5 % for power and ±0.15 % for frequency. Readings are refreshed every 1.0 s and shown on an OLED display. RS-485 and USB interfaces with the Modbus RTU protocol allow data to be passed to supervisory systems. The inputs are galvanically isolated at no less than 2500 V. The unit mounts on a DIN rail and operates from -40 to +70 °C. Typical applications include power engineering, metallurgy, the chemical and food industries, and other industrial sectors.

Network type
Single-phase
Input signals
2, separate I and U
Voltage measurement (direct connection)
AC (2.6...260 V), 45 to 65 Hz
Voltage measurement (via external transformer)
AC (2.6×10^-3...4000×10^3 V), 45 to 65 Hz

Technical specifications

Network typeSingle-phase
Input signals2, separate I and U
Voltage measurement (direct connection)AC (2.6...260 V), 45 to 65 Hz
Voltage measurement (via external transformer)AC (2.6×10^-3...4000×10^3 V), 45 to 65 Hz
Measurement update period1.0 s
Resolution (voltage)0.1 V
Basic reduced error limit (voltage)± 0.25 %
Maximum permissible input voltage (≤ 1 s)520.0 V
Current measurement (direct connection)0.05 to 5.0 A
Current measurement (via external transformer)(0.05×10^-3 ... 50.0×10^3) A
Resolution (current)0.01 (on display), 0.001 (via interface)
Basic reduced error limit (current)± 0.25 %
Maximum permissible input current (≤ 1 s)10.0 A
Measured poweractive, W/kW; reactive, var/kvar; apparent, VA/kVA (instantaneous, average, accumulated)
Power calculation time1.0 s
Basic reduced error limit (power)± 0.5 %
Power factor measuring range0.0 to 1.0
Basic reduced error limit (cosφ)± 1.0 %
Fundamental frequency measuring range45.0 to 65.0 Hz
Basic reduced error limit (frequency)± 0.15 %
Galvanic isolation voltage (inputs)not less than 2500 V
Galvanic isolation voltage (internal units)not less than 500 V
Analogue output (option)4–20 mA / R ≤ 500 Ω
Discrete outputs (option)NPN transistor: up to 40 V, 100 mA; normally open relay: up to 230 V, 5 A
Data interfaceRS-485, USB
Data protocolModbus RTU
DisplayOLED display
Supply voltage (DC)24 V
Supply voltage (AC)230 V
Consumption (DC)not more than 100 mA
Power consumption (AC)≤ 2.0 VA
MountingDIN rail (DIN35x7,5 EN50022)
Weightnot more than 0.3 kg
Housing size (HxWxD)96x54x58 mm
Degree of protectionIP20
Ambient temperature-40 °C to +70 °C
StandardsДСТУ EN 60529:2014, ДСТУ IEC 60654-1:2001, ДСТУ IEC 60654-3:2001, ДСТУ EN 61326-1, ДСТУ IEC 60381-1
Ordering code structureІПМ-101-АА-BB-DD-R-U

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The version is defined by the ordering code ІПМ-101-АА-BB-DD-R-U. For the voltage (АА) and current (BB) inputs, choose direct connection for networks up to 260 V and currents up to 5.0 A, or connection via an external transformer for higher values. Position DD specifies the output module: none, 4–20 mA analogue, NPN transistor or relay. Position R sets whether RS-485 is fitted, and position U sets the supply: 24 V DC or 230 V AC.

Similar products

Test and measurement

Request a price and lead time

ІПМ-101 — single-phase network parameter indicator. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.