ІПМ-101 — single-phase network parameter indicator
Country: Ukraine · Model: ІПМ-101
AC 2.6...260 V (direct connection) · 0.05...5.0 A (direct connection) · U and I error ±0.25 % · 45...65 Hz
The ІПМ-101 is a panel indicator for monitoring the electrical parameters of a single-phase network. Measured signals are applied to two separate inputs, one for voltage and one for current. From these, the unit determines voltage, current, fundamental frequency and power factor. It also calculates active, reactive and apparent power as instantaneous, average and accumulated values. With direct connection, it covers AC 2.6...260 V and 0.05...5.0 A, and external transformers extend these ranges considerably. The basic reduced error is ±0.25 % for voltage and current, ±0.5 % for power and ±0.15 % for frequency. Readings are refreshed every 1.0 s and shown on an OLED display. RS-485 and USB interfaces with the Modbus RTU protocol allow data to be passed to supervisory systems. The inputs are galvanically isolated at no less than 2500 V. The unit mounts on a DIN rail and operates from -40 to +70 °C. Typical applications include power engineering, metallurgy, the chemical and food industries, and other industrial sectors.
- Network type
- Single-phase
- Input signals
- 2, separate I and U
- Voltage measurement (direct connection)
- AC (2.6...260 V), 45 to 65 Hz
- Voltage measurement (via external transformer)
- AC (2.6×10^-3...4000×10^3 V), 45 to 65 Hz
Technical specifications
| Network type | Single-phase |
|---|---|
| Input signals | 2, separate I and U |
| Voltage measurement (direct connection) | AC (2.6...260 V), 45 to 65 Hz |
| Voltage measurement (via external transformer) | AC (2.6×10^-3...4000×10^3 V), 45 to 65 Hz |
| Measurement update period | 1.0 s |
| Resolution (voltage) | 0.1 V |
| Basic reduced error limit (voltage) | ± 0.25 % |
| Maximum permissible input voltage (≤ 1 s) | 520.0 V |
| Current measurement (direct connection) | 0.05 to 5.0 A |
| Current measurement (via external transformer) | (0.05×10^-3 ... 50.0×10^3) A |
| Resolution (current) | 0.01 (on display), 0.001 (via interface) |
| Basic reduced error limit (current) | ± 0.25 % |
| Maximum permissible input current (≤ 1 s) | 10.0 A |
| Measured power | active, W/kW; reactive, var/kvar; apparent, VA/kVA (instantaneous, average, accumulated) |
| Power calculation time | 1.0 s |
| Basic reduced error limit (power) | ± 0.5 % |
| Power factor measuring range | 0.0 to 1.0 |
| Basic reduced error limit (cosφ) | ± 1.0 % |
| Fundamental frequency measuring range | 45.0 to 65.0 Hz |
| Basic reduced error limit (frequency) | ± 0.15 % |
| Galvanic isolation voltage (inputs) | not less than 2500 V |
| Galvanic isolation voltage (internal units) | not less than 500 V |
| Analogue output (option) | 4–20 mA / R ≤ 500 Ω |
| Discrete outputs (option) | NPN transistor: up to 40 V, 100 mA; normally open relay: up to 230 V, 5 A |
| Data interface | RS-485, USB |
| Data protocol | Modbus RTU |
| Display | OLED display |
| Supply voltage (DC) | 24 V |
| Supply voltage (AC) | 230 V |
| Consumption (DC) | not more than 100 mA |
| Power consumption (AC) | ≤ 2.0 VA |
| Mounting | DIN rail (DIN35x7,5 EN50022) |
| Weight | not more than 0.3 kg |
| Housing size (HxWxD) | 96x54x58 mm |
| Degree of protection | IP20 |
| Ambient temperature | -40 °C to +70 °C |
| Standards | ДСТУ EN 60529:2014, ДСТУ IEC 60654-1:2001, ДСТУ IEC 60654-3:2001, ДСТУ EN 61326-1, ДСТУ IEC 60381-1 |
| Ordering code structure | ІПМ-101-АА-BB-DD-R-U |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
The version is defined by the ordering code ІПМ-101-АА-BB-DD-R-U. For the voltage (АА) and current (BB) inputs, choose direct connection for networks up to 260 V and currents up to 5.0 A, or connection via an external transformer for higher values. Position DD specifies the output module: none, 4–20 mA analogue, NPN transistor or relay. Position R sets whether RS-485 is fitted, and position U sets the supply: 24 V DC or 230 V AC.
Similar products
Request a price and lead time
ІПМ-101 — single-phase network parameter indicator. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.