ІПМ-113-1 — three-phase network parameter indicator

U and I accuracy ±0.25 % · ~1...400 V (direct connection) · 0.05–5.0 A (direct connection) · 45.0–65.0 Hz

The ІПМ-113-1 is an indicator for monitoring the parameters of a three-phase AC network. It measures voltage, current, frequency, power and power factor, and calculates instantaneous, averaged and accumulated values. The inputs connect either directly (voltage up to 400 V, current up to 5.0 A) or through external voltage and current transformers. With transformers, the range extends to 4000×10^3 V and 50.0×10^3 A. Accuracy is ±0.25 % for voltage and current, ±0.5 % for power and ±0.15 % for frequency. Readings appear on an OLED display with a keypad. Data are transmitted over RS-485 using the Modbus RTU protocol, and configuration is carried out via USB. Three discrete outputs (NPN transistor or relay) provide signalling. Galvanic isolation voltage is at least 2500 V. The IP20 housing mounts on a DIN rail, and the operating temperature range is -40 °C to +70 °C. Typical applications are electricity distribution monitoring and energy efficiency projects.

Supply voltage
~90 V to ~264 V
Power consumption
≤ 2.0 VA
Voltage range (direct connection)
~ (1...400 V)
Voltage range (via transformer)
~ (1×10^-3...4000×10^3 V)

Technical specifications

Supply voltage~90 V to ~264 V
Power consumption≤ 2.0 VA
Voltage range (direct connection)~ (1...400 V)
Voltage range (via transformer)~ (1×10^-3...4000×10^3 V)
Current range (direct connection)0.05 to 5.0 A
Current range (via transformer)(0.05х10^-3 ... 50.0х10^3) A
Frequency range45.0 Hz to 65.0 Hz
Voltage accuracy± 0.25 %
Current accuracy± 0.25 %
Power accuracy± 0.5 %
Power factor (cos φ) accuracy± 1.0 %
Frequency accuracy± 0.15 %
Maximum input voltage800.0 V
Maximum input current10.0 A
Galvanic isolation voltageat least 2500 V
Discrete outputs3 (NPN transistor / relay)
InterfacesRS-485, USB
ProtocolModbus RTU
DisplayOLED display
Networkthree-phase
MountingDIN rail
Degree of protectionIP20
Operating temperature-40 °C to +70 °C
Dimensions98х110х57 mm
Weightmax. 0.3 kg
ІПМ-113-2 version2 discrete outputs (NPN / relay), 1 analogue output, 98х100х57 mm
ІПМ-113-3 versionno discrete or analogue outputs, 98х72х57 mm

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The ІПМ-113 series comes in three versions. The ІПМ-113-1 has three discrete outputs (NPN or relay) and measures 98х110х57 mm. The ІПМ-113-2 suits applications that need an analogue output: it has 2 discrete outputs, 1 analogue output and measures 98х100х57 mm. The ІПМ-113-3 has no discrete or analogue outputs; at 98х72х57 mm it is the most compact version, intended for indication only.

Similar products

Test and measurement

Request a price and lead time

ІПМ-113-1 — three-phase network parameter indicator. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.