ІПМ-113-1 — three-phase network parameter indicator
Country: Ukraine · Model: ІПМ-113-1
U and I accuracy ±0.25 % · ~1...400 V (direct connection) · 0.05–5.0 A (direct connection) · 45.0–65.0 Hz
The ІПМ-113-1 is an indicator for monitoring the parameters of a three-phase AC network. It measures voltage, current, frequency, power and power factor, and calculates instantaneous, averaged and accumulated values. The inputs connect either directly (voltage up to 400 V, current up to 5.0 A) or through external voltage and current transformers. With transformers, the range extends to 4000×10^3 V and 50.0×10^3 A. Accuracy is ±0.25 % for voltage and current, ±0.5 % for power and ±0.15 % for frequency. Readings appear on an OLED display with a keypad. Data are transmitted over RS-485 using the Modbus RTU protocol, and configuration is carried out via USB. Three discrete outputs (NPN transistor or relay) provide signalling. Galvanic isolation voltage is at least 2500 V. The IP20 housing mounts on a DIN rail, and the operating temperature range is -40 °C to +70 °C. Typical applications are electricity distribution monitoring and energy efficiency projects.
- Supply voltage
- ~90 V to ~264 V
- Power consumption
- ≤ 2.0 VA
- Voltage range (direct connection)
- ~ (1...400 V)
- Voltage range (via transformer)
- ~ (1×10^-3...4000×10^3 V)
Technical specifications
| Supply voltage | ~90 V to ~264 V |
|---|---|
| Power consumption | ≤ 2.0 VA |
| Voltage range (direct connection) | ~ (1...400 V) |
| Voltage range (via transformer) | ~ (1×10^-3...4000×10^3 V) |
| Current range (direct connection) | 0.05 to 5.0 A |
| Current range (via transformer) | (0.05х10^-3 ... 50.0х10^3) A |
| Frequency range | 45.0 Hz to 65.0 Hz |
| Voltage accuracy | ± 0.25 % |
| Current accuracy | ± 0.25 % |
| Power accuracy | ± 0.5 % |
| Power factor (cos φ) accuracy | ± 1.0 % |
| Frequency accuracy | ± 0.15 % |
| Maximum input voltage | 800.0 V |
| Maximum input current | 10.0 A |
| Galvanic isolation voltage | at least 2500 V |
| Discrete outputs | 3 (NPN transistor / relay) |
| Interfaces | RS-485, USB |
| Protocol | Modbus RTU |
| Display | OLED display |
| Network | three-phase |
| Mounting | DIN rail |
| Degree of protection | IP20 |
| Operating temperature | -40 °C to +70 °C |
| Dimensions | 98х110х57 mm |
| Weight | max. 0.3 kg |
| ІПМ-113-2 version | 2 discrete outputs (NPN / relay), 1 analogue output, 98х100х57 mm |
| ІПМ-113-3 version | no discrete or analogue outputs, 98х72х57 mm |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
The ІПМ-113 series comes in three versions. The ІПМ-113-1 has three discrete outputs (NPN or relay) and measures 98х110х57 mm. The ІПМ-113-2 suits applications that need an analogue output: it has 2 discrete outputs, 1 analogue output and measures 98х100х57 mm. The ІПМ-113-3 has no discrete or analogue outputs; at 98х72х57 mm it is the most compact version, intended for indication only.
Similar products
Request a price and lead time
ІПМ-113-1 — three-phase network parameter indicator. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.