ІПМ-2 — single-phase AC voltage indicator-converter
Country: Ukraine · Model: ІПМ-2
accuracy class 0.4 · input 1÷10 V … 50÷500 V AC · measurement period 0.1 s · RS-485, Modbus RTU
The ІПМ-2 is a microprocessor-based digital voltmeter and signal converter for single-phase AC networks. It measures the RMS value of the voltage and shows the reading on a 4-digit display with signalling LEDs. The incoming analogue signal is digitised and processed. The measured value can then be passed on as a standardised analogue signal or through a discrete output (NPN transistor or relay). It can also be sent over an RS-485 interface using Modbus RTU for SCADA integration. Measurement error does not exceed 0.4 %, the measurement period is 0.1 s and the galvanic isolation voltage is at least 1500 V. The unit runs from a ~100…~230 V mains supply or from 24 V DC. It operates from -40 °C to +70 °C and is used in the energy sector, metallurgy, the chemical and food industries, process automation systems and other industrial fields.
- Input signal range
- 1÷10 V; 1.5÷15 V; 3÷30 V; 4÷40 V; 5÷50 V; 6÷60 V; 10÷100 V; 25÷250 V; 30÷300 V; 50÷500 V; from transformer
- Measured quantity
- RMS AC voltage, single-phase network
- Measurement error
- ≤ 0.4 %
- Accuracy class
- 0.4
Technical specifications
| Input signal range | 1÷10 V; 1.5÷15 V; 3÷30 V; 4÷40 V; 5÷50 V; 6÷60 V; 10÷100 V; 25÷250 V; 30÷300 V; 50÷500 V; from transformer |
|---|---|
| Measured quantity | RMS AC voltage, single-phase network |
| Measurement error | ≤ 0.4 % |
| Accuracy class | 0.4 |
| Measurement period | 0.1 s |
| AC supply voltage | ~100 … ~230 V |
| DC supply voltage | 24 V |
| Power consumption (AC) | ≤ 4.0 VA |
| Current consumption (DC) | max. 110 mA |
| Galvanic isolation voltage | min. 1500 V |
| Interface / protocol | RS-485 / Modbus RTU |
| Analogue output (option) | 0–5 mA, 0–20 mA, 4–20 mA, 0–10 V |
| Discrete output (option) | NPN transistor or relay |
| Display | 4-digit digital display, signalling LEDs |
| Configuration | via front panel or software |
| Mounting | panel, DIN rail |
| Panel cutout | 45+0.8 × 92+0.8 mm |
| Mounting depth | max. 135 mm |
| Degree of protection | IP30 |
| Operating temperature | -40 °C to +70 °C |
| Dimensions | 48х96х106 mm |
| Weight | max. 0.25 kg |
| Versions | ІПМ-2-01-0 — input 1–10 V, no output; ІПМ-2-03-1 — input 3–30 V, analogue output 0–5 mA |
| Standards | ДСТУ IEC 60381-1; ДСТУ IEC 60654-1:2001; ДСТУ IEC 60654-3:2001; ГОСТ 12971 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the input range to suit the monitored network voltage: from 1÷10 V up to 50÷500 V, or a transformer input. Next, choose the output type: analogue (0–5 mA, 0–20 mA, 4–20 mA, 0–10 V), discrete (NPN or relay) or none. Then specify the mounting: panel or DIN rail. For example, ІПМ-2-01-0 has a 1–10 V input and no output, while ІПМ-2-03-1 has a 3–30 V input and a 0–5 mA output.
Similar products
Request a price and lead time
ІПМ-2 — single-phase AC voltage indicator-converter. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.