Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

ІТМ-101 — single-channel process indicator with bar graph

accuracy ≤ 0.2 % · response time ≤ 0.1 s · RS-485, Modbus RTU · 48 × 96 mm panel housing

The ІТМ-101 is a single-channel microprocessor indicator for panel mounting. It measures and displays process variables such as temperature, pressure, flow and level. The unit accepts standard current signals (0–5, 0–20, 4–20 mA) and voltage signals (0–10 V, 0–50 mV, 0–200 mV, 0–1 V). It also works with thermocouples, resistance temperature detectors and resistance inputs of 0–1000 Ohm. The measured value appears on a 4-digit 7-segment display, backed by a horizontal bar graph. Accuracy is within 0.2 % and response time is no more than 0.1 s. An RS-485 interface running Modbus RTU connects the indicator to automation systems. An analogue output or a discrete output (NPN transistor, relay or solid-state relay) is available as an option. Outputs and the interface are galvanically isolated at ≥ 1500 V. The unit runs from ~100…230 V mains or 24 V DC and operates from -40 °C to +70 °C. Typical users include the energy sector, metallurgy, and the chemical and food industries, as well as process control systems.

Channels
1
Accuracy
≤ 0.2 %
Response time
≤ 0.1 s
Display
4-digit 7-segment, bar graph

Technical specifications

Channels1
Accuracy≤ 0.2 %
Response time≤ 0.1 s
Display4-digit 7-segment, bar graph
Current and voltage inputs0–5 mA, 0–20 mA, 4–20 mA, 0–10 V, 0–50 mV, 0–200 mV, 0–1 V
ThermocouplesTХA, TХК, ТЖК, ТХКн, ТПП10, ТПР, ТВР-1
RTDsPt 500, Pt 1000, ТСМ, ТСП, NTC
Resistance0–1000 Ohm
Analogue output (optional)0–5 mA, 0–20 mA, 4–20 mA, 0–10 V
Discrete output (optional)NPN transistor (≤ 40 V, 100 mA), relay (230 V, 8 A), solid-state relay (60 V, 1 A)
Passive sensor supply (optional)24 V, 25 mA
InterfaceRS-485
ProtocolModbus RTU
Supply voltage~100…230 V, 50 Hz; 24 V DC
Power consumption≤ 4.0 VA (AC), ≤ 180 mA (DC)
Galvanic isolation≥ 1500 V (outputs/interface), input not isolated
Front panel layouthorizontal (ІТМ-101, 31-segment bar graph), vertical (ІТМ-101В, 21-segment bar graph)
Mountingpanel, 48 × 96 mm cutout, 135 mm mounting depth
Dimensions48 × 96 × 106 mm
Weight≤ 0.25 kg
Degree of protectionIP30
Operating temperature-40 °C to +70 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Choose the front-panel layout: ІТМ-101 is horizontal with a 31-segment bar graph, while ІТМ-101В is vertical with 21 segments. To pass the signal on to a control system, order an analogue output (0–5, 0–20, 4–20 mA or 0–10 V). For alarm duties, order a discrete output: NPN transistor, 230 V / 8 A relay or 60 V / 1 A solid-state relay. A 24 V, 25 mA supply option is available for passive sensors.

Similar products

Test and measurement

Request a price and lead time

ІТМ-101 — single-channel process indicator with bar graph. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.