The ІТМ-110Н is a single-channel microprocessor indicator for monitoring process variables such as temperature, pressure, humidity, flow and level. It accepts signals from thermocouples, resistance thermometers, current or voltage transmitters, and resistive or NTC sensors. The unit processes the input and shows the value on a four-digit seven-segment display. Basic reduced measurement error is ≤ 0.2 %, and the input is polled in up to 0.1 second. The device provides an active analogue output (0–5, 0–20, 4–20 mA or 0–10 V) and two discrete outputs for alarm and control functions. Data exchange with a supervisory system runs over RS-485 using Modbus RTU in slave or master mode. All circuits are galvanically isolated from one another, with an isolation voltage of at least 1500 V. The indicator mounts on a DIN rail and operates from -40 °C to +70 °C. Typical applications include power generation, metallurgy, and the chemical, food and other industries.

Device type
Process indicator
Analogue inputs
1
Current and voltage inputs
0–5 mA, 0–20 mA, 4–20 mA, 0–75 mV, 0–200 mV, 0–2 V, 0–10 V
Resistance thermometers
ТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, Pt500, Pt1000

Technical specifications

Device typeProcess indicator
Analogue inputs1
Current and voltage inputs0–5 mA, 0–20 mA, 4–20 mA, 0–75 mV, 0–200 mV, 0–2 V, 0–10 V
Resistance thermometersТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, Pt500, Pt1000
ThermocouplesТХА (K), ТХК (L), ТЖК (J), ТПП 10 (S), ТПР (B), ТХКн (E), ТВР-1 (A-1)
Resistive inputs0–1 kΩ, NTC (0–1 kΩ, 0–3 kΩ, 0–5 kΩ, 0–10 kΩ)
Temperature measuring range0–2500 °C
Basic reduced measurement error≤ 0.2 %
Input polling timeup to 0.1 s
Galvanic isolationfull, all circuits isolated; isolation voltage (outputs and interface) at least 1500 V
Analogue output1, active
Output signal ranges0–5 mA / R ≤ 2000 Ω; 0–20 mA / R ≤ 500 Ω; 4–20 mA / R ≤ 500 Ω; 0–10 V / R ≤ 2 kΩ
Output signal error≤ 0.2 %
Discrete outputs2
Discrete output typesNPN transistor: up to 40 V, 100 mA; changeover relay: up to 230 V, 8 A; solid-state relay: up to 60 V, 1 A
InterfaceRS-485
ProtocolModbus RTU (slave, master)
Displayseven-segment digital, 4 digits
Supply voltage230 V AC / 24 V DC
Power consumption (AC)≤ 6.5 VA
Non-volatile memoryyes, EEPROM
MountingDIN rail
Dimensions (HxWxD)94х106х58 mm
Weightmax. 0.35 kg
Degree of protectionIP30
Ambient temperature-40 °C to +70 °C
StandardsДСТУ 2858-94, ДСТУ 2837-94, ГОСТ3044-94, DIN IEC 584-1, ДСТУ EN 60529:2014, ДСТУ IEC 60654-1:2001, ДСТУ IEC 60654-3:2001, ГОСТ 22261-94, ГОСТ 15150-69, ГОСТ 26828, ГОСТ 12971, ГОСТ 23170

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

When ordering, specify the supply voltage (230 V AC or 24 V DC) and the discrete output type. An NPN transistor (up to 40 V, 100 mA) suits controller logic inputs. A changeover relay (up to 230 V, 8 A) is intended for power circuits. A solid-state relay (up to 60 V, 1 A) is recommended for frequent contactless switching. Choose the analogue output range to match the input of the receiving device.

Similar products

Test and measurement

Request a price and lead time

ІТМ-110Н — single-channel industrial indicator. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.